[ 1 ] - Biomechanical Evaluation of Temperature Rising and Applied Force in Controlled Cortical Bone Drilling: An Animal in Vitro Study

Background: The present study was conducted to quantify the relationships between bone drilling process parameters(i.e., feed rate, resting time, exit rate, and drill bit diameter) and drilling outcome parameters (i.e., thrust force andmaximum temperature).Methods: This study utilized 10-cm cortical bovine samples to evaluate the effects of four independent parameters,in...