X-ray spectra calculation for different target-filter of mammograms using MCNP Code

author

Abstract:

 ABSTRACTBackground: An electron beam generated X-ray spectrum consists of characteristic X-ray and continuous bermsstrahlung. The aim of this research is calculating and comparing X-ray spectra for different target filter of mammograms. Materials and Methods: Monte Carlo is a very powerful tool to simulate a series of different target-filter assembly in order to calculate the X-ray spectra. MCNP version 4C has been used for simulation set up to calculate X-ray spectra for different target-filter combination of mammograms. Results: The spectra of different and the most commonly used target– filter in mammography equipments (Mo-Mo, Mo-Rh, Rh-Rh, W-Rh, Mo-Al and Rh-Al) have been calculated.  Conclusion: The computational results can be used to select a suitable X-ray spectrum for mammography as well as for computing the absorbed dose. Also, the Monte Carlo result of Mo-Mo is in good agreement with the published results.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

x-ray spectra calculation for different target-filter of mammograms using mcnp code

abstractbackground: an electron beam generated x-ray spectrum consists of characteristic x-ray and continuous bermsstrahlung. the aim of this research is calculating and comparing x-ray spectra for different target filter of mammograms. materials and methods: monte carlo is a very powerful tool to simulate a series of different target-filter assembly in order to calculate the x-ray spectra. mcn...

full text

Calculation of the X-Ray Spectrum of a Mammography System with Various Voltages and Different Anode-Filter Combinations Using MCNP Code

Introduction One of the best methods in the diagnosis and control of breast cancer is mammography. The importance of mammography is directly related to its value in the detection of breast cancer in the early stages, which leads to a more effective treatment. The purpose of this article was to calculate the X-ray spectrum in a mammography system with Monte Carlo codes, including MCNPX and MCNP5...

full text

calculation of the x-ray spectrum of a mammography system with various voltages and different anode-filter combinations using mcnp code

introduction one of the best methods in the diagnosis and control of breast cancer is mammography. the importance of mammography is directly related to its value in the detection of breast cancer in the early stages, which leads to a more effective treatment. the purpose of this article was to calculate the x-ray spectrum in a mammography system with monte carlo codes, including mcnpx and mcnp5...

full text

assessment of mean glandular dose in mammography system with different anode-filter combinations using mcnp code

conclusion by comparing the results, we saw that w/rh anode/filter combination is the best choice in breast mammography imaging because of the lowest delivered dose in comparison with w/ag and rh/al. moreover, breast thickness and g value have significant effects on mgd. objectives the aim of this study was to determine the average absorbed dose of x-ray radiation in the glandular tissue of the...

full text

Assessment of Mean Glandular Dose in Mammography System with Different Anode-Filter Combinations Using MCNP Code

BACKGROUND X-ray mammography is one of the general methods for early detection of breast cancer. Since glandular tissue in the breast is sensitive to radiation and it increases the risk of cancer, the given dose to the patient is very important in mammography. OBJECTIVES The aim of this study was to determine the average absorbed dose of X-ray radiation in the glandular tissue of the breast d...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 3  issue None

pages  129- 133

publication date 2005-12

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023