Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy.

Authors

  • Haghparast , Abas 2. PhD of Medical physics, Kermanshah University of Medical Sciences, Kermanshah,Iran
  • Pashton shayesteh , Sajad 1. M.Sc of Medical physics, Kermanshah University of Medical Sciences, Kermanshah,Iran
  • Seidi, Masomeh Instructor, Education Development Center,Hamadan University of Medical Sciences,Hamadan,Iran
  • Taghi Pour , Mostafa
Abstract:

Background & Objective: Radiotherapy has a very special significance in the treatment of cancer. Beam radiation therapy using photons and electrons produced by a linear accelerator is used extensively in the treatment of breast Cancer. In this article, In addition to providing a description of three techniques of radiotherapy in the treatment of breast cancer, has been Evaluating the effectiveness of this method in the base of uniformity of the dose distribution in the target volume in breast cancer as an important factor in the effectiveness of treatment by radiation.Materials & Methods: Photon, electron and arc Techniques in radiotherapy have been implemented practically using phantom trunk and EDRII films. At the time of practical Techniques, films were placed between the slice of the phantom and were irradiated under selected conditions and the data of these images are analyzed by MATLAB software.Results: Studies show that as a result of using adjacent fields in whole radiotherapy techniques, Parts of the target volume received dose twice or more than the prescribed dose. Meanwhile, by the photon dose technique, rate of receiving dose is more uniform and closer to the prescribed dose.Conclusion: According to scientific studies done by different protocols in breast radiotherapy, tangential photon technique has very less overlap of the field by comparison to other methods and more uniform dose distribution than the prescribed dose .In The base of this research results can be announced the photon techniques in breast cancer treatment was preferred over other methods.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Dosimetric Evaluation of Target Volume in Breast Boost Radiotherapy: Comparison of Electron and Photon Beam

Background and purpose: Breast‑conserving surgery followed by radiation therapy to the whole breast is now recognized as a standard strategy in patients with breast cancer. Recommended technique for radiotherapy is whole breast irradiation followed by boost to the tumor bed. This study aimed to compare the dosimetric parameters of electron and photon beams for boosting irradia­tion in post‑lump...

full text

The Effect of Breast Reconstruction Prosthesis on Photon Dose Distribution in Breast Cancer Radiotherapy

Introduction: Siliconeprosthetic implants are commonlyutilizedfor tissue replacement and breast augmentation after mastectomy. On the other hand, some patients require adjuvant radiotherapy in order to preventlocal-regional recurrence and increment ofthe overall survival. In case of recurrence, the radiation oncologist might have to irradiate the prosthesis.The aim of this study was to evaluate...

full text

Effect of uniform magnetic field on dose distribution in the breast radiotherapy

Background: To reduce the dose to normal tissues surrounding the treated breast, a uniform magnetic field was used within a humanoid phantom in breast radiotherapy. Materials and Methods: Monte Carlo simulations were performed with GEANT4, irradiating humanoid phantoms in a magnetic field. To reconstruct phantoms, computed tomography (CT) data slices of four patients were used for the Monte Car...

full text

Comparison of “heart and lung volume absorbed dose” between electron and photon boost radiotherapy after breast conserving surgery

Background: Breast conserving surgery (BCS) followed by radiotherapy (RT) has been widely accepted as the standard treatment in early stages of invasive breast cancer. The standard technique of RT includes whole breast irradiation (WBI). Additional tumor bed boost irradiation has also an important role in the local tumor control. But there are various controversial delivery methods. The aim of ...

full text

Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...

full text

Review of techniques for improving the uniformity of dose distribution in total body irradiation (TBI) with parallel – opposed anterior and posterior geometry

      Total body irradiation (TBI) is a kind of external beam radiotherapy which is used in conjunction with chemotherapy with the purpose of immunosuppression before bone marrow transplantation. As recommended by AAPM dose distribution uniformity in TBI is very important and dose variation must be within ±10% of prescription dose. Patients treatment geometry for TBI techniques fall into two co...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 3  issue 4

pages  355- 362

publication date 2014-03

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023