Thyroid dose and dose reduction method from CT scan of head and neck
Authors
Abstract:
Introduction: Computed tomography (CT) consists of 11% of all imaging methods, but accounts for approximately 67% of radiation exposure due to diagnostic cases. More than one-third of all CT scans are done in the head and neck area. The thyroid gland is irradiated during CT head and neck. According to studies, this gland has the highest levels of radiation-induced cancer, and in children, due to longer life expectancy than adults, cancer has a greater chance of developing and developing. Therefore, awareness of the amount of thyroid dose and dose reduction methods are essential. Results: According to the results, when performing CT scans of the head and neck, thyroid gland radiation is very high, but the use of optimization techniques leads to a decrease in the amount of thyroid receiving dose. Dose optimization is divided into three stage s: 1-Before scanning 2- During the scan, which includes: patient position, scan parameters, and shields inside and outside the field; 3- After scanning, which includes: rehabilitation filter and quality control. For example, the use of protective shields during head and neck CT tests leads to a reduction in the thyroid dose of approximately 40% to 60%. Conclusion: According to the principle of ALARA, the aim of applying optimization techniques is to reduce the amount of thyroid receiving dose while mainta ining image quality. The most effective of these techniques in head and neck CT scans is the use of protective shield that minimizes the thyroid dose
similar resources
Optimization of Parameters in 16-slice CT-scan Protocols for Reduction of the Absorbed Dose
Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for...
full textThyroid shield during brain CT scan: dose reduction and image quality evaluation
Introduction Radiation doses during CT examinations are known to be relatively high and provide over 3540% of the collective radiation received from diagnostic imaging procedures [1]. The extensive use of CT and raised concerns about growing radiation exposure is empathizing the need for appropriate strategies to optimize and thereby, if possible, reduce radiation dose due to CT. Cancer risks a...
full textOptimization of Head CT Protocol to Reduce the Absorbed Dose in Eye Lenses and Thyroid: A Phantom Study
Introduction: Utilization of computed tomography (CT) scans is increasing annually. This study aimed to reduce the absorbed dose of sensitive organs in the head (eye lenses and thyroid) and to assess changes in resultant images quality in head scans when the radiation dose is decreased. Material and Methods: An anthropomorphic phantom was examined with head protocols in both helical and sectio...
full textDose Distribution Analysis of Rapid Arc and Intensity Modulated Radiotherapy Plan in Head and Neck Cancer
Introduction: Globally, intensity-modulated radiation therapy (IMRT) is considered as highly precise and accurate method of radiotherapy planning. This technique amplifies spatial dose distribution conformity by modulating the intensity of radiation beams in each sub-volume. Additionally, it can reduces the dose to surrounding critical organs and deliver the planned dose to targets with the nom...
full textMetal Artifact Reduction of Dental Fillings in Head and Neck CT Images
Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...
full textMeasurement of the Adsorbed Radiation Dose to Eyelens During CT Scan and Radiotherapy of Nasopharynx Cancer
Introduction: The study of the cause of death during the last few decades has shown that death due to infectious diseases has been declining and has been rising due to noninvasive diseases, especially cancers and accidents. Cancer is considered as one of the fatal diseases, and every year, more than 10.9 million people worldwide are diagnosed with the disease. Mater...
full textMy Resources
Journal title
volume 15 issue Special Issue-12th. Iranian Congress of Medical Physics
pages 87- 87
publication date 2018-12-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023