Thermal modeling of mini-channel and laminated Types evaporator in mobile air conditioning system

Authors

  • M. Dehghandokht
Abstract:

In this paper, mini-channel type evaporator which is new in mobile air conditioning (MAC) or automotive air conditioning (AAC) systems is thermally modeled. The performance of mini-channel evaporator is also compared with the laminated evaporator which is being currently used in automotive industries. The mini-channel evaporator was constructed of two rows of parallel flow mini-channel tubes with inlet and outlet headers. The numerical results of modeling the laminated and mini-channel evaporators validated with the corresponding experimental data which was obtained from experiments performed on mobile air conditioning system in calorimeter test bench. The comparison of modeling results of two evaporators showed good agreement with experimental data. The performance of laminated and mini-channel evaporators were also compared under various operating conditions. The mini-channel evaporator had higher cooling capacity (7.2%) and higher refrigerant pressure drop (45%) in comparison with the corresponding values in laminated evaporator assuming the same external geometry. The outlet air temperature and enthalpy of minichannel evaporator was also lower, 11% and 8% respectively, than that for laminated evaporator. This cause to reduce the time period as well as power/fuel consumption for reaching the comfortable cabin temperature.

Download for Free

Sign up for free to access the full text

Already have an account?login

similar resources

Modelling Of An Automotive Multi-Evaporator Air-Conditioning System

An automotive multi-evaporator air conditioning system, which is composed of two evaporators and a secondary fluid cooler, was modeled using the LMS Imagine.Lab Amesim® 1D software. The present study focuses on understanding the dynamic coupling of the several loop components such as the three evaporators having different cooling capacities. This kind of multi-evaporator air-conditioning system...

full text

Adjustable throat-area expansion valves used in automotive air conditioning systems: A mini review

Adjustable throat-area expansion valves (ATAEV) are functioned as area regulator control units. In literatures, there are many expansion valves normally used in automotive air-conditioning systems, as regulator and electrical type valves. Nevertheless, a review study for such issue has not been introduced, according to the best of author knowledge. The present paper presents a review study for ...

full text

Performance and Reliability Degradation of a Residential Unitary Air Conditioning System Resulting from a Mismatch of a 1992 Air Conditioning Unit with a 15-20 Year Old Evaporator

Fred Keller Split Systems Director The National Appliance Energy Conservation Act has established a minimum efficiency of 10 SEER for residential split system air conditioners and heat pumps. Approximately 50% of residential split system air conditioners are sold as replacements for units having much lower SEER levels, typically 5-9 Btu/W·h. This investigation assessed the detrimental affects t...

full text

A Model of an Air-Conditioning Condenser and Evaporator with Emphasis on In-Tube Enhancement

A MODEL OF AN AIR-CONDITIONING CONDENSER AND EVAPORATOR WITH EMPHASIS ON IN-TUBE ENHANCEMENT Kuo-Hsiu Huang Michael B. Pate Mechanical Engineering Department Iowa state University Ames, Iowa 50011 A computational model for air-conditioning condensers and evaporators with in-tube enhancement has been developed. The purpose of this model is to provide a tool for the design of plate tinned-tube he...

full text

Fully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology

The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...

full text

stability and attraction domains of traffic equilibria in day-to-day dynamical system formulation

در این پژوهش مسئله واگذاری ترافیک را از دید سیستم های دینامیکی فرمول بندی می کنیم.فرض کرده ایم که همه فاکتورهای وابسته در طول زمان ثابت باشند و تعادل کاربر را از طریق فرایند منظم روزبه روز پیگیری کنیم.دینامیک ترافیک توسط یک نگاشت بازگشتی نشان داده می شود که تکامل سیستم در طول زمان را نشان می دهد.پایداری تعادل و دامنه جذب را توسط مطالعه ویژگی های توپولوژیکی تکامل سیستم تجزیه و تحلیل می کنیم.پاید...

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 2  issue 2

pages  68- 83

publication date 2012-04

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023