The need for national diagnostic reference levels: Entrance surface dose measurement in intraoral radiography

Authors

  • A. Kavousi
  • A. Shareghi
  • F. Nazeri
  • H. Mozdarani
  • M. Ghiassi-Nejad
  • M. Jafari-Zadeh
Abstract:

Background: Intraoral radiographies are the most frequent X-ray examinations in humans. According to International Commission on Radiation Protection (ICRP) recommendations, the selection of a diagnostic reference level (DRL) should be specific to a country or region. Critica l organs such as thyroid gland are exposed to X-rays in intraoral radiography and these exposures should be kept as low as reasonably achievable. To assist the development of DRLs for intraoral radiography, a National Radiation Protection Department-sponsored pilot study was carried out. Materials and Methods: Thermoluminescent dosimetry (TLD) is widely acknowledged to be the recommended method for measuring entrance surface doses (ESD). In this study, ESD was measured using LiF thermoluminescent dosimeters (TLD-100) on the skin (either mandibular or maxillary arcs) of 40 patients. Three TLD chips were placed on the skin of each patient. The doses were averaged for each radiography and mean ESD of all patients calculated. Results: The mean ± SD entrance surface dose at the center of the beam on the patients' skin in intraoral radiography was 1.173 ± 0.606 mGy (ranged from 0.01 to 0.40 mGy). The mean ESD for male and female patients were 1.380 ± 0.823, and 1.004 ± 0.258 respectively. No statistically significant difference was found between these means. Despite its necessity, in national level, there is no published data on the diagnostic reference levels for intraoral radiography. However, the results obtained in this study are lower than those reported by investigators in other countries. Conclusion: In IR Iran, due to lack of large scale studies, no diagnostic reference levels have been set for X-ray diagnostic procedures. Due to lack of national diagnostic reference levels, it is not possible to clarify whether in intraoral radiographies any dose reduction techniques are needed. We intend to perform similar nationwide studies to set the diagnostic reference level for intraoral radiography. Iran . J. Radiat. Res., 2004 2 (3): 127-133

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

the need for national diagnostic reference levels: entrance surface dose measurement in intraoral radiography

background: intraoral radiographies are the most frequent x-ray examinations in humans. according to international commission on radiation protection (icrp) recommendations, the selection of a diagnostic reference level (drl) should be specific to a country or region. critica l organs such as thyroid gland are exposed to x-rays in intraoral radiography and these exposures should be kept as low ...

full text

Paediatric Dose AssessmentToward Establishment of National Diagnostic Reference Levels for Digital Radiography Examinations in Iran

Introduction: Paediatric patients deserve special attention because of the higher radiation risks compared with adults. The main purpose of this study is to determine patient dose and diagnostic reference level for Paediatric through Entrance Surface Dose (ESD) calculations in common X-ray examination and to establish Paediatric national DRLs in digital radiography in Iran. <...

full text

Entrance surface dose measurement on the thyroid gland in orthopantomography: The need for optimization

Background: The anatomic position and proven radiosensitivity of the thyroid make it an organ of concern in dental X-ray examinations. A National Radiation Protection Department (NRPD)-sponsored pilot study carried out in the Dental Radiology Department of RUMS., to assess if the radiation dose in panoramic radiographies could be reduced without significant impairment of the subjective image qu...

full text

Diagnostic reference levels in intraoral dental radiography in Korea

PURPOSE The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. MATERIALS AND METHODS One hundred two intraoral dental radiographic machines from all regions of South Korea were selected...

full text

entrance surface dose measurement on the thyroid gland in orthopantomography: the need for optimization

background: the anatomic position and proven radiosensitivity of the thyroid make it an organ of concern in dental x-ray examinations. a national radiation protection department (nrpd)-sponsored pilot study carried out in the dental radiology department of rums., to assess if the radiation dose in panoramic radiographies could be reduced without significant impairment of the subjective image qu...

full text

Diagnostic reference levels at intraoral and dental panoramic examinations

Background: The aim of this study was to measure and determine diagnostic reference levels (DRLs) of programs used at intraoral and dent panoramic examinations in Kosovo. Materials and Methods: To determine DRL, were performed measurements for dose area product (DAP) at intraoral and dental panoramic radiology systems. This study has covered over 47% of X-ray units, which are in use for intraor...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 2  issue None

pages  127- 133

publication date 2004-12

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023