The influence of neutron contamination on pacemaker in photon beam radiotherapy by LINAC using the Monte Carlo method

Authors

  • Asghar Hadadi Islamic Azad University, Science and Research Branch, Tehran University of Medical Sciences, Tehran, Iran. .
  • Maryam Dehghanpour Islamic Azad University, Science and Research Branch, Tehran University of Medical Sciences, Tehran, Iran. . E- mail:[email protected]. Tel: +98 9166692961
  • Reza Molazadeh Department of Cardiology, Imam Khomeini Hospital, Tehran University of Medical Sciences
  • Somayeh Gholami Department of Radiotherapy, Cancer Institute, Tehran University of Medical Sciences
Abstract:

Introduction: In radiation therapy with high-energy photon beams (E > 7 MeV) neutrons are generated mainly in LINACs head thorough (γ, n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the protocol TG-34, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in the functioning of the pacemaker. So, in the radiotherapy of patients with pacemakers, the system should be designed to limit the dose of the pacemaker to 2Gy. In the current study, the Varian Clinac 2100C linear accelerator head and the pacemaker were fully simulated, the neutron and photon flux were evaluated by the FLUKA code. Materials and Methods: The linear accelerator Varian 2100c is simulated in 18 MeV energy using FLUKA code. A 70 × 40 × 20 cm3 water phantom simulated upper body of patient, at a distance of 100 cm from the source (SSD). According to the MIRD Phantom, the prostate is simulated at a depth of 4.5 cm from the phantom surface at a distance of 50 cm from the pacemaker. All components of the heart pacemaker, including battery and circuit parts, leads and connector were simulated according to real case. The results of the simulation were compared with measurements to verify the simulated model. Results: According to the distribution results of neutron flux around the head, the jaws despite of guide and control of photon beam toward the phantom, these components are not an effective barrier to neutron contamination, but also because of the heavy elements used in them, exacerbate the production of neutrons. The highest level of contamination is in target, due to photoneutron production in tungsten. Moreover, the distribution of neutron flux in the water phantom and the pacemaker shows a relative increase in neutron flux at a depth of 2 cm in the water phantom caused by the effect of build-up and neutron accumulation that is due to the neutron scattering within the phantom. Conclusion: For the treatment of prostate cancer where the pacemaker is located more than 40 cm from the treatment field, the neutron flux is observed in a wide range of thermal neutrons to fast. Therefore, in addition to the target tissue that receives the highest unwanted neutron dose during treatment, close organs and, subsequently, other organs receive a considerable dose of neutrons. The highest amount of flux on the surface of the titanium body of the pacemaker is for 100 keV photons and the most of the neutron flux is in the thermal region. The results of photon and neutron flux in the battery layers show that the maximum flux is in steel layer and then for lithium.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Assessment of Neutron Contamination Originating from the Presence of Wedge and Block in Photon Beam Radiotherapy

Background: One of the main causes of induction of secondary cancer in radiation therapy is neutron contamination received by patients during treatment.Objective: In the present study the impact of wedge and block on neutron contamination production is investigated. The evaluations are conducted for a 15 MV Siemens Primus linear accelerator. Methods: Simulations were performed using MCNPX Monte...

full text

An assessment of the Photon Contamination due to Bremsstrahlung Radiation in the Electron Beams of a NEPTUN 10PC Linac using a Monte Carlo Method

Introduction: In clinical electron beams, most of bremsstrahlung radiation is produced by various linac head structures. This bremsstrahlung radiation dose is influenced by the geometry and construction of every component of the linac treatment head structures. Thus, it can be expected that the amount of the contaminated photon dose due to bremsstrahlung radiation varies among different linacs,...

full text

The plastic tray effect on the spectrum of photoneutrons prudused by 18 MV medical linac using the Monte Carlo method

Introduction: One of the important problems of using high energy linacs is the production of photoneutrons. High energy medical linacs produce secondary neutrons. These phtoneutrons increase patient dose   Materials and Methods: In this study, the effect of plastic trays on spectrum of photoneutrons produced by 18MV linac is investigated using the MCNP4C code...

full text

Monte Carlo estimation of electron contamination in a 18 MV clinical photon beam

Background: The electron contamination may reduce or even diminish the skin sparing property of the megavoltage beam. The detailed characteristics of contaminant electrons are presented for different field sizes and cases. Materials and Methods: The Monte Carlo code, MCNPX, has been used to simulate 18 MV photon beam from a Varian Linac-2300 accelerator. All dose measurements were car...

full text

assessment of neutron contamination originating from the presence of wedge and block in photon beam radiotherapy

background: one of the main causes of induction of secondary cancer in radiation therapy is neutron contamination received by patients during treatment. objective: in the present study the impact of wedge and block on neutron contamination production is investigated. the evaluations are conducted for a 15 mv siemens primus linear accelerator.  methods: simulations were performed using mcnpx mon...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  205- 205

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023