The Effect of High Penetration Level of Distributed Generation Sources on Voltage Stability Analysis in Unbalanced Distribution Systems Considering Load Model
Authors
Abstract:
Static voltage stability is considered as one of the main issues for primary identification before voltage collapsing in distribution systems. Although, the optimum siting of distributed generation resources in distribution electricity network can play a significant role in voltage stability improving and losses reduction, the high penetration level of them can lead to reduction in the improvement of load-ability. Moreover, the rapid variation and types of loads in distribution networks will have a significant impact on the maximum load-ability across the whole system. In this paper, a modified voltage stability index is presented with regard to distributed generation units (DG) along with two-tier load model. By applying the Imperialist Competition Algorithm (ICA), the best size of DG with corresponding of DG placement is used to improve the voltage stability and reducing the losses. It is shown in the paper that the DG penetration level can have influence on load-ability of the system and also the voltage regulators performance. The simulation results on the standard IEEE-13 Bus test feeder illustrate the precision of studies method and the load-ability limits in the system, taking into account the high penetration level of distributed generation units.
similar resources
coordination of protective schemes in distribution and subtransmission systems including distributed generation
نصب منابع پراکنده در سیستم های توزیع و فوق توزیع علاوه بر مزیت های فراوان، مشکلاتی را هم به همراه دارد. یکی از این مشکلات تأثیر این منابع روی اندازه جریان های اتصال کوتاه است. به طور معمول از حفاظت های مبتنی بر اصل جریان زیاد در سیستم های توزیع و فوق توزیع استفاده می شود. از مهمترین طرح های حفاظتی استفاده شده در فیدرهای توزیع، حفاظت فیوز- ریکلوزر است. همچنین از طرح های حفاظتی جریان زیاد جهتی در...
Distributed Voltage Control in Distribution Networks with High Penetration of Photovoltaic Systems
In this paper, a distributed method for reactive power management in a distribution system has been presented. The proposed method focuses on the voltage rise where the distribution systems are equipped with a considerable number of photovoltaic units. This paper proposes the alternating direction method of multipliers (ADMMs) approach for solving the optimal voltage control problem in a distri...
full textthe effect of authentic listening materials on the listening proficiency of efl learners in the intermediate level
having conducted the experiment and analysed the data, the researcher computed the groups mean scores and variances for the test relating to the research question. as the final atep, a t-test was conodonted for the hypothesis. as noted earlier, the significance level was determined at .05 and .01 respectively. the observed t-value was higher than the critical t-value at. 5 and .01 levels. conse...
15 صفحه اولDetermining the Optimal Location and Amount of Distributed Generation Sources in an Unbalanced Radial Distribution Grid
Optimal placement of scattered generator sources in the main and secondary feeders of radial grid reduces energy losses, releases the capacity of existing feeders and improves the existing voltage profile. In this project determine the location and suitable for the production of production resources S cattered in radial feeders of unbalanced distribution networks, a new formulation solution is ...
full textA New Load-Flow Method in Distribution Networks based on an Approximation Voltage-Dependent Load model in Extensive Presence of Distributed Generation Sources
Power-flow (PF) solution is a basic and powerful tool in power system analysis. Distribution networks (DNs), compared to transmission systems, have many fundamental distinctions that cause the conventional PF to be ineffective on these networks. This paper presents a new fast and efficient PF method which provides all different models of Distributed Generations (DGs) and their operational modes...
full textthe washback effect of discretepoint vs. integrative tests on the retention of content in knowledge tests
در این پایان نامه تاثیر دو نوع تست جزیی نگر و کلی نگر بر به یادسپاری محتوا ارزیابی شده که نتایج نشان دهندهکارایی تستهای کلی نگر بیشتر از سایر آزمونها است
15 صفحه اولMy Resources
Journal title
volume 7 issue 2
pages 196- 205
publication date 2019-10-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com