The effect of CT contrast agents on treatment planning and dose calculation in radiation therapy of pelvis cancers

Authors

  • Behzad Changizi Master of Medical Physics, Isfahan University of Medical Sciences, Isfahan, Iran. Tell: 0098-09363271261, Email:
  • Daryoush Shahbazi Professor of Medical Physics at Isfahan University of Medical Sciences, Isfahan, Iran. Tell:0098-091316786, Email: [email protected]
Abstract:

Introduction: Using contrast medium in diagnosis and identifying of an organ from its surrounding tissue is very useful. These contrast mediums alter radiation absorption of studied organs. The aim of this study is to identify the influences of contrast media in treatment planning system of the pelvis.   Materials and Methods: Seven patients with pelvis area cancer with two sets of CT image, one with contrast medium and another without it, have been used and influences of contrast medium in treatment planning system for these patients were studied.   Results: After using contrast medium 2.63% increase in MU for RL field and 0.79%, 1.05%, 1.42% decrease in MU for AP, PA, RL fields have been obtained in rectum, respectively. For Bladder cancer, 0.34% decrease in MU of AP filed and 1.57%, 0.46%, 0.39% increase in MU for PA, RL and LL fields have been calculated, respectively. For cervix cancer, 1.1% decrease for AP field and 0.68% increase for PA field have been obtained. Conclusion: According to the DVHs and calculated MUs, the results showed that the dose differences between the plans for the CT images with and without contrast medium were less than about 1% and was clinically tolerable.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

the washback effect of discretepoint vs. integrative tests on the retention of content in knowledge tests

در این پایان نامه تاثیر دو نوع تست جزیی نگر و کلی نگر بر به یادسپاری محتوا ارزیابی شده که نتایج نشان دهندهکارایی تستهای کلی نگر بیشتر از سایر آزمونها است

15 صفحه اول

Impact of contrast agents on dose algorıthms of planning systems

Background: Use of contrast agents (CAs) during CT simulation for treatment planing system leads to changes in  electron density. In this study we aimed to investigate the effect on  calculated dose of various concentrations of CAs on treatment planing systems in different dose calculation algorithms. Materials and Methods: Contrast agent (0.769 mg/ml Iopromid) - water mixtures at con...

full text

the effects of planning on accuracy and complexity of iranian efl students’ written narrative task performance

this study compared the different effects of form-focused guided planning vs. meaning-focused guided planning on iranian pre-intermediate students’ task performance. the study lasted for three weeks and concentrated on eight english structures. forty five pre-intermediate iranian students were randomly assigned to three groups of guided planning focus-on-form group (gpfg), guided planning focus...

15 صفحه اول

the effect of taftan pozzolan on the compressive strength of concrete in the environmental conditions of oman sea (chabahar port)

cement is an essential ingredient in the concrete buildings. for production of cement considerable amount of fossil fuel and electrical energy is consumed. on the other hand for generating one tone of portland cement, nearly one ton of carbon dioxide is released. it shows that 7 percent of the total released carbon dioxide in the world relates to the cement industry. considering ecological issu...

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  335- 335

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023