Test-retest reliability and minimal detectable change for center of pressure measures of postural stability in elderly subjects

Authors

  • Ali Esteki Shahid beheshti University of Medical Science, Tehran, Iran.
  • Ismaeil Ebrahimi-Takamjani Iran University of Medical Science, Tehran, Iran.
  • Mohammad Parnianpour Sharif industrial University, Tehran, Iran.
  • Nader Maroufi Iran University of Medical Science, Tehran, Iran.
  • Reza Salehi School of Rehabilitation Science, Iran University of Medical Science
Abstract:

  Abstract   Background: Postural instability has been identified as a potential precursor of   falls in elderly subjects. Postural stability in quiet stance is commonly assessed with   center of pressure (COP) measures. The purpose of this study was to determine testretest reliability and minimal detectable change (MDC) for the center of pressure   (COP) measures in the elderly subjects.   Methods: Eighteen healthy elderly people over the age of 60 years participated in   this study. For each subject the COP was recorded during quiet upright stance on different levels of postural difficulty (eyes open versus eyes closed, firm surface versus   foam surface) and lean condition (forward and backward). All measurements were   done on two sessions with 7 days interval. These indices: mean velocity, standard deviation of amplitude, standard deviation of velocity, phase plane parameter and area   (95% confidence ellipse). Intraclass correlation coefficient (ICC), standard error of   measurement (SEM) and coefficient of variation (CV) were used to quantify testretest   reliability. The MDC for each measure was calculated to quantify intervention   effects.   Results: In general, test-retest reliability of COP measures in the elder subjects   was increased whenever postural difficulty of task increased in quiet standing. In   standing conditions, mean velocity and phase plane parameter were the most sensitive   and the most reliable measures. The lean range was the most sensitive and the   most reliable measure, in the lean conditions.   Conclusion: Center of pressure measures in the quiet standing especially in difficult   postural conditions demonstrated high sensitivity in the older subjects. These results   may be useful in quantification and assessment of balance performance and   treatment efficacy.  

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

test-retest reliability and minimal detectable change for center of pressure measures of postural stability in elderly subjects

abstract   background: postural instability has been identified as a potential precursor of falls in elderly subjects. postural stability in quiet stance is commonly assessed with center of pressure (cop) measures. the purpose of this study was to determine testretest reliability and minimal detectable change (mdc) for the center of pressure (cop) measures in the elderly subjects.   methods: ei...

full text

The Test-Retest Reliability and Minimal Detectable Change of the Fugl-Meyer Assessment of the Upper Extremity and 9-Hole Pegboard Test in Individuals With Subacute Stroke

Purpose: The first step to manage motor impairment of upper limb in patients with subacute stroke is having an accurate assessment tool. The Fugl-Meyer assessment of upper extremity and 9-hole pegboard test are used to evaluate motor function and hand dexterity in stroke survivals. The present study aimed to investigate the test-retest reliability and minimal detectable change (MDC) in these tw...

full text

Test-Retest Reliability of Dynamic Postural Stability Measures in Healthy and Chronic Non-specific Low Back Pain Groups

Objective: The primary aim of the present study was to study the reliability of postural stability measures during whole body dynamic conditions, so they can be used in postural stability evaluations, investigations of injury mechanisms and assessments of treatment efficacy. Materials & Methods: Twelve healthy volunteers and 12 low back pain patients performed repeated trunk bending motions ...

full text

Test-retest reliability of linear and nonlinear measures of postural stability during visual deprivation in healthy subjects

[Purpose] The purpose of this study is to evaluate the reliability of linear and nonlinear measures of the center of pressure (COP) during visual deprivation. [Subjects and Methods] Fifteen young adults participated in this study. COP signals were recorded in two conditions: eyes open and eyes closed. Three trials were performed in each condition with a rest period of approximately 1 min. The i...

full text

the test-retest reliability and minimal detectable change of the fugl-meyer assessment of the upper extremity and 9-hole pegboard test in individuals with subacute stroke

purpose: the first step to manage motor impairment of upper limb in patients with subacute stroke is having an accurate assessment tool. the fugl-meyer assessment of upper extremity and 9-hole pegboard test are used to evaluate motor function and hand dexterity in stroke survivals. the present study aimed to investigate the test-retest reliability and minimal detectable change (mdc) in these tw...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 23  issue 4

pages  224- 232

publication date 2010-02

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023