Survey of the Use of X-ray Beam Collimator and Shielding Tools during Infant Chest Radiography

Authors

  • Abdolreza Gilavand Employed Expert on Faculty Appointments at Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
  • Mansour Zabihzadeh Assistant Professor, Department of Medical Physics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
  • Nasim Shams Deparment of Oral and Maxillofacial Radiology, Faculty of Dentistry, Jundishapur University of Medical Sciences, Ahvaz, Iran.
  • Vahid Karami Medical Physics Student, Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
Abstract:

Background The use of shielding tools and X-ray beam collimator has extensively been advocated as effective methods to reduce radiation exposure to patients underwent radiological procedures. The aim of this study was to address the use of these protection measures during infant chest radiography. Material and Methods 348digital and/or analogue infant chest radiographs were reviewed that performed between October-  and December 2015 at four main hospitals of Khuzestan-Iran province to assessment the beam collimation. For each radiograph the area between current and acceptable collimation was calculated. Thirty eight radiographers were deeply interviewed to investigate the actual use of shielding tools and the main reasons for not using of them. Results Only 54 (15.5%) radiographs [33(61%) analogues and 21(39%) digital] have satisfactory collimation. The total means area of diagnostic interest (ADI) and the region outside ADI for each radiograph was estimated 171 and 86 cm2, respectively. The irradiated region outside the ADI was significantly larger in digital than in analogue images (mean of 103 cm2 vs. 54 cm2; P < 0.05). Shielding tools were used regularly only by 5% of radiographers. Conclusion The radiosensitive organs of infants located outside of ADI in hospitals investigated are at risk. Adherence to safety guideline urgently recommends.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

survey of the use of x-ray beam collimator and shielding tools during infant chest radiography

background the use of shielding tools and x-ray beam collimator has extensively been advocated as effective methods to reduce radiation exposure to patients underwent radiological procedures. the aim of this study was to address the use of these protection measures during infant chest radiography. material and methods 348digital and/or analogue infant chest radiographs were reviewed that perfor...

full text

the survey of the virtual higher education in iran and the ways of its development and improvement

این پژوهش با هدف "بررسی وضعیت موجود آموزش عالی مجازی در ایران و راههای توسعه و ارتقای آن " و با روش توصیفی-تحلیلی و پیمایشی صورت پذیرفته است. بررسی اسنادو مدارک موجود در زمینه آموزش مجازی نشان داد تعداد دانشجویان و مقاطع تحصیلی و رشته محل های دوره های الکترونیکی چندان مطلوب نبوده و از نظر کیفی نیز وضعیت شاخص خدمات آموزشی اساتید و وضعیت شبکه اینترنت در محیط آموزش مجازی نامطلوب است.

Patient effective dose evaluation for chest X-ray examination in three digital radiography centers

Background: The radiation doses resulting from diagnostic X-ray examinations are routinely measured in terms of entrance surface dose (ESD) and effective dose (ED). In this study, for the purpose of radiation protection, the radiation doses received from Digital chest X-ray examination were evaluated in terms of ESD and ED. Material and Methods: The ED was calculated by using the MCNP ...

full text

a structural survey of the polish posters

تصویرسازی قابلیتهای فراوانی را دارا است

15 صفحه اول

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 4  issue 4

pages  1637- 1642

publication date 2016-04-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023