Surface Activation of NiTi Alloy by Using Electrochemical Process for Biomimetic Deposition of Hydroxyapatite Coating (TECHNICAL NOTE)
Authors
Abstract:
Electrochemical depositions of calcium phosphate (Ca-P) film on NiTi alloy in concentrated simulated body flood (SBF×5) were carried out by cathodic polarization. The Ca-P layer was successfully deposited on Ni-Ti alloy substrate under 10mA/cm2 current density for 2 hours at room temperature. Then, in order to investigate the bioactivity of the pre-calcified samples, they were immersed in SBF for 1 and 3 days. The microstructure, composition and bioactivity of the coatings were evaluated by using scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR) techniques. Results showed that the activation of the surface of the NiTi alloy by electrochemical process can significantly enhance the biomimetic deposition during time. On the other hand, by increasing immersion time of pre-calcified samples in SBF from 1 to 3 days, the biomimetic coating uniformly covered the surface of the sample. The ratio of the Ca/P for the pre-calcified sample after immersion in SBF for 3 days was about 1.5 which is very close to the Ca/P ratio of stoichiometric hydroxyapatite.
similar resources
Characterization of Constrained Aged Niti Strips for Using In Artificial Muscle Actuators (Technical Note)
Marvelous bending/straightening effects of two-way shape memory alloy (TWSMA) help their employment in design and manufacturing of new medical appliances. Constrained ageing with bending load scheme can induce two-way shape memory effect (TWSME). Scanning electron microscope (SEM) analysis, electrical resistivity measurement (ERM) and differential scanning calorimetry (DSC) are employed to dete...
full textElectrodeposition of Nano Hydroxyapatite Coating on Biodegradable Mg-Zn Scaffold (TECHNICAL NOTE)
Magnesium has been recently recognized as a biodegradation metal for bone substitute application. In the present work, porous magnesium-zinc scaffolds were prepared by powder metallurgical process and nano hydroxyapatite (HAP) coating on the Mg-3Zn (wt.%) scaffold was prepared by pulse electrodeposition and alkali treatment processes to improve the corrosion resistance of scaffold. The results ...
full textBiomimetic Hydroxyapatite Coating on Metal Implants
The combination of the high mechanical strength of metals with the osteoconductive properties of calcium phosphates make hydroxyapatite coatings on titanium implants widely used in orthopedic surgery. However, the most popular coating method, plasma spraying, exhibits some important drawbacks: the inability to cover porous implants and to incorporate biologically active agents, delamination, an...
full textHydroxyapatite Coating on Silicon Nitride Surfaces Using the Biomimetic Method
Silicon nitride based ceramics are promising candidates for biomedical applications due to their chemical and dimensional stability associated to suitable mechanical strength and relatively high fracture toughness. However, the bioinert characteristics of these ceramics limit their application to situations where the formation of chemical bonds between the material and the tissue are not essent...
full textstudy of cohesive devices in the textbook of english for the students of apsychology by rastegarpour
this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...
ELECTRODEPOSITION OF NANO SIZE HYDROXYAPATITE COATING ON TI ALLOY
A film of osteoconductive and biocompatible material on biomedical metallic implants can create bioactivity of the implant and shorten healing time. Hydroxyapatite, that is the most important mineral part of human bone, was coated on Ti6Al4V using cathodic electrode position process. Pulse electrode position technique was used and the effects of different parameters such as potential, duty cycl...
full textMy Resources
Journal title
volume 27 issue 10
pages 1627- 1634
publication date 2014-10-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com