Abstract:

The resonant frequency and sensitivity of an atomic force microscope (AFM) cantilever with assembled cantilever probe (ACP) have been analyzed and a closed-form expression for the sensitivity of vibration modes has been obtained. The proposed ACP comprises an inclined cantilever and extension, and a tip located at the free end of the extension, which makes the AFM capable of topography at sidewalls of microstructures. Because the extension is not exactly located at one end of the cantilever, the cantilever is modeled as two beams. In this study, the effects of the interaction stiffness and damping, and also some geometrical parameters of the cantilever on the resonant frequencies and sensitivities are investigated. Afterwards, the influence of the interaction stiffness and damping, and the geometrical parameters such as the angles of the cantilever and extension, the connection position of the extension and the ratio of the extension length to the cantilever length on the sensitivity and resonant frequency are investigated. The results show that the greatest flexural modal sensitivity occurs at a small contact stiffness of the system, when the connection position and damping are also small. The results also indicate that at low values of contact stiffness, an increase in the cantilever slope or a decrease in the angle between the cantilever and extension can rise the resonant frequency while reduces the sensitivity.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

study of the flexural sensitivity and resonant frequency of an inclined afm cantilever with sidewall probe

the resonant frequency and sensitivity of an atomic force microscope (afm) cantilever with assembled cantilever probe (acp) have been analyzed and a closed-form expression for the sensitivity of vibration modes has been obtained. the proposed acp comprises an inclined cantilever and extension, and a tip located at the free end of the extension, which makes the afm capable of topography at sidew...

full text

Study of the size-dependant vibration behavior of an AFM microcantilever with a sidewall probe

In this paper, the resonant frequency and sensitivity of an atomic force microscope (AFM) with an assembled cantilever probe (ACP) are analyzed utilizing the modified couple stress theory. The proposed ACP comprises a horizontal microcantilever, an extension and a tip located at the free end of the extension, which make AFM capable of scanning the sample sidewall. First, the governing different...

full text

an investigation about the relationship between insurance lines and economic growth; the case study of iran

مطالعات قبلی بازار بیمه را به صورت کلی در نظر می گرفتند اما در این مطالعه صنعت بیمه به عنوان متغیر مستفل به بیمه های زندگی و غیر زندگی شکسته شده و هم چنین بیمه های زندگی به رشته های مختلف بیمه ای که در بازار بیمه ایران سهم قابل توجهی دارند تقسیم میشود. با استفاده از روشهای اقتصاد سنجی داده های برای دوره های 48-89 از مراکز ملی داده جمع آوری شد سپس با تخمین مدل خود بازگشتی برداری همراه با تعدادی ...

15 صفحه اول

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 6  issue 4

pages  351- 362

publication date 2015-10-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023