Stator Turn-to-Turn Fault Detection of Induction Motor by Non-Invasive Method Using Generalized Regression Neural Network

author

  • H. Yaghobi Faculty of Electrical and Computer Engineering, Semnan University, Semnan, Iran.
Abstract:

Condition monitoring and protection methods based on the analysis of the machine's current are widely used according to non-invasive characteristics of current transformers. It should be noted that, these sensors are installed by default in the machine control center. On the other hand, condition monitoring based on mathematical methods has been proposed in literature. However, they are model based and are too complex. Artificial neural network (ANN) methods are robust and less model dependent for fault diagnosis when the fault signature can be directly achieved using the sampling data. In this procedure, the state of internal process will be ignored. Therefore, generalized regression neural network (GRNN) based method is presented in this paper that uses negative sequence currents (calculated from the machine's currents) as inputs to detect and locate an inter-turn fault in the stator windings of the induction motor. Turn-to-turn fault by changing the contact resistance and various numbers of shorted turns for realizing the fault severity has been modeled by Matlab/Simulink. The simulation and experimental results show that the proposed method is effective for the diagnosis of stator inter-turn fault in induction motor under the supply voltage unbalances.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Stator Inter-turn Fault Detection in Inverter Fed Induction Motor Drives

Received Mei 9, 2017 Revised Jun 20, 2017 Accepted Jul 27, 2017 The Squirrel Cage Induction motor(SCIM) with advanced power electronic inverters presents the greater advantages on cost and energy efficiency as compared with other industrial solutions for varying speed applications. In recent, the inverter fed induction motors are being popular in the industries. These inverter fed-motors are re...

full text

Recognition and Location of Power Transformer Turn to Turn Fault by Analysis of Winding Imposed Forces

Turn to turn fault is one of the major internal failures in the power transformers that if it is not quickly detected, can be extended and led to a complete transformer breakdown. So, the diagnosis and location of the turn to turn fault of the power transformer, as one of the most important equipment in the power system, is the main objective of this paper. For this purpose, a detailed model of...

full text

intelligent determining amount of inter-turn stator winding fault in permanent magnet synchronous motor using an artificial neural network trained by improved gravitational search algorithm

extension of inter-turn fault in windings of pmsm can damage all parts of electrical systems, and in some cases in sensitive applications may lead to irreparable events. identification of such small faults at incipient steps can be so helpful to protect entire part of electrical system. in this paper, intelligent protection system is designed which is made by two major parts. in the first part ...

full text

Optimal Rotor Fault Detection in Induction Motor Using Particle-Swarm Optimization Optimized Neural Network

This study examined and presents an effective method for detection of failure of conductor bars in the winding of rotor of induction motor in low load conditions using neural networks of radial-base functions. The proposed method used Hilbert method to obtain the stator current signal push. The frequency and signal amplitude of the push stator were used as the input of the neural network and th...

full text

Stator Turn-to-turn Fault Detection of Synchronous Generator Using Total Harmonic Distortion (thd) Analyzing of Magnetic Flux Linkage

Diagnostics of synchronous generator turn-to-turn faults can be accomplished by analyzing the anomalies of machine local variable such as magnetic flux linkage. On the other hand, because current transformers and voltage transformers are usually installed in the machine for different purposes as default, the monitoring schemes that depend on the study of these inputs have become a topic of inte...

full text

A Fuzzy Based Stator Inter-Turn Fault Diagnosis of Three Phase Induction Motor

This paper deals with detection and diagnosis of Stator Inter turn fault of three phase Induction motor. The proposed method is based on the stator current Clarke vector pattern. Three phase stator currents are used to construct Clarke vector pattern in order to distinguish the “healthy” and “faulty” condition of induction motor. The covered area for each pattern is calculated and the per unit ...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 13  issue 1

pages  77- 88

publication date 2017-03

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023