Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum
Authors
Abstract:
In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that were obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL-1 and 2-20 μg mL-1 in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.64, and accuracy (relative error) was better than 2.49%. Developed method in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. Also, the proposed technique was successfully applied to spiked human serum samples. No electroactive interferences from the endogenous substances were found in human serum.
similar resources
square wave voltammetric determination of diclofenac in pharmaceutical preparations and human serum
in this study, a simple and reliable square wave voltammetric (swv) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. the proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 m tbaclo4/acetonitrile solution. the well-defined two oxidation peaks were observed at 0.87 and 1.27 v, respectively. cal...
full textSquare wave voltammetric determination of valproic acid in pharmaceutical Preparations
The electrochemical behavior of valproic acid (VAL) was investigated using square wave voltammetry, cyclic voltammetry, and sampled direct current polarography and a new square wave voltammetric method was developed for determination of VAL in pharmaceutical preparations. VAL showed two reduction peaks at about –0.2 V and –0.8 V vs. Ag/AgCl 3 M KCl with a hanging mercury drop electrode in 0.05 ...
full textDifferential pulse voltammetric determination of diclofenac in pharmaceutical preparations and human serum
This article describes a differential pulse voltammetric (DPV) method for the determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electro-oxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that obtaine...
full textDetermination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods
In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containin...
full textMy Resources
Journal title
volume 14 issue 3
pages 715- 722
publication date 2015-06-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023