Skin Dosimetry of Some Beta Sources using the VARSKIN2 Code

Authors

  • Ali Asghar Mowlavi Associate Professor, Physics Dept., School of Sciences, Sabzevar Tarbiat Moallem University, Iran
  • Azam Sadat Afzali M.Sc., in Physics, School of Sciences, Sabzevar Tarbiat Moallem University, Iran
Abstract:

Introduction: Skin dose and depth dose distribution of some beta sources that can contaminate skin or protective clothing covering the skin have been calculated using VARSKIN2. Materials and Methods: In this research, absorbed dose to skin and depth dose from the skin surface have been calculated for 90Sr/90Y, 147Pm, 32P beta emitter radioisotopes by using input parameters: activity of source, cover thickness, cover density, air gap thickness, radiation time and different source geometries. Results: Absorbed dose variation was calculated for beta sources in different source forms, namely, point, 2-D disk, cylindrical, spherical and slab sources. The results show that a cylindrical source causes the minimum damage to skin cells. Therefore, this shape of source is the best with respect to radiation protection. Discussion and conclusion: The VARSKIN2 code is a very useful tool for skin dosimetry, as well being fast, accurate and user friendly. It can be used for dose optimization calculations especially for beta sources over human skin.  

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

skin dosimetry of some beta sources using the varskin2 code

introduction: skin dose and depth dose distribution of some beta sources that can contaminate skin or protective clothing covering the skin have been calculated using varskin2. materials and methods: in this research, absorbed dose to skin and depth dose from the skin surface have been calculated for 90sr/90y, 147pm, 32p beta emitter radioisotopes by using input parameters: activity of source, ...

full text

Adding 166Ho data to VARSKIN2 code and dose calculation to human skin

Background: Skin cancer can be treated by various methods. Electron radiotherapy has been a useful therapeutic modality in the treatment of skin cancers in areas which are difficult to cure by other methods. Depth dose distribution of 166Ho using VARSKIN2 code is presented in this work. Material and Methods: Depth dose distribution of 166Ho was calculated, using VARSKIN2 code by adding...

full text

Effectiveness Evaluation of Skin Covers against Intravascular Brachytherapy Sources Using VARSKIN3 Code

Background and Objective: The most common intravascular brachytherapy sources include 32P, 188Re, 106Rh and 90Sr/90Y. In this research, skin absorbed dose for different covering materials in dealing with these sources were evaluated and the best covering material for skin protection and reduction of absorbed dose by radiation staff was recognized and recommended.Method: Four materials including...

full text

adding 166ho data to varskin2 code and dose calculation to human skin

background: skin cancer can be treated by various methods. electron radiotherapy has been a useful therapeutic modality in the treatment of skin cancers in areas which are difficult to cure by other methods. depth dose distribution of 166ho using varskin2 code is presented in this work. material and methods: depth dose distribution of 166ho was calculated, using varskin2 code by adding of 166ho...

full text

effectiveness evaluation of skin covers against intravascular brachytherapy sources using varskin3 code

background and objective: the most common intravascular brachytherapy sources include 32p, 188re, 106rh and 90sr/90y. in this research, skin absorbed dose for different covering materials in dealing with these sources were evaluated and the best covering material for skin protection and reduction of absorbed dose by radiation staff was recognized and recommended. method: four materials includin...

full text

assessment of the efficiency of s.p.g.c refineries using network dea

data envelopment analysis (dea) is a powerful tool for measuring relative efficiency of organizational units referred to as decision making units (dmus). in most cases dmus have network structures with internal linking activities. traditional dea models, however, consider dmus as black boxes with no regard to their linking activities and therefore do not provide decision makers with the reasons...

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 6  issue Issue 3,4

pages  73- 81

publication date 2009-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023