Simultaneous electrochemical determination of Acetaminophen and Codeine based on a MWCNT/MCM48 nanocomposite modified glassy carbon
Authors
Abstract:
A novel chemically modified electrode was constructed based on multi-walled carbon nanotubes, MCM48 molecular sieve composite modified glassy carbon electrode .The modified electrode showed that it can be used for simultaneous determination of acetaminophen (ACT) and codeine (COD), simultaneously. The measurements were carried out by the application of differential pulse voltammetry (DPV), cyclic voltammetry (CV) and chronoamperometry (CA) methods. The fabricated sensor revealed some advantages such as excellent selectivity, good stability and high sensitivity toward ACT and COD determination. Application of DPV method under the optimum conditions showed the modified electrode provides linear responses versus ACT concentrations in the range of 0.2-40 µM and 80-350 µM. The results for COD showed the linear responses in the ranges of 4-70 µM and 150-400 µM respectively using DPV method. The modified electrode was used for determination of ACT and COD in real samples like human blood serum and plasma with satisfactory results.
similar resources
Electrochemical behavior and determination of clozapine on a glassy carbon electrode modified by electrochemical oxidation.
The adsorptive and electrochemical behaviors of clozapine (CLZ) were investigated on a glassy carbon electrode that was electrochemically treated by anodic oxidation at +1.8 V, following potential cycling in the potential range from -0.8 to 1.0 V vs. Ag/AgCl reference electrode. Based on the obtained electrochemical results, an electrochemical-chemical (EC) mechanism was proposed to explain the...
full textA New Hydroxylamine Electrochemical Sensor Based on an Oxadiazol Derivative and Multi-wall Carbon Nanotuhes Modified Glassy Carbon Electrode
A new hydroxylamine sensor has been fabricated by immobilizing oxadiazol denvative at the surface ol aglassy carbon electrode (GCE) modified by multi-wall carbon nanotube (MIVCNT). The adsorbed thin Illms oroxadiazol derivative on the MWCNT modified GCE show a pair of peaks with surface confined characierisnus.The oxadiazol derivative MWCNI (OMWCNT) modified GCE shows highly catalytic activity ...
full textElectrochemical Sensor for Determination of Fenitrothion at Multi-wall Carbon Nanotubes Modified Glassy Carbon Electrode
A sensor, based on multi-wall carbon nanotubes modified glassy carbon electrode (MWCNT/GCE), was developed for determination of fenitrothion. Determining the surface area of MWCNT/GCE showed that this surface is three times more active than that of a glassy carbon electrode. The experimental parameters, such as the amount of MWCNTs, pH of the fenitrothion solution, preconcentration potential an...
full textStudy and Electrochemical Determination of Tyrosine at Graphene Nanosheets Composite Film Modified Glassy Carbon Electrode
A graphene nanosheets (GNS) film coated glassy carbon electrode (GCE) was fabricated for sensitive determination of tyrosine (Tyr). The GNS-based sensor was characterized by scanning electron microscope and electrochemical impedance spectroscopy. The voltammetric techniques were employed to study electro-oxidation of Tyr. The results revealed that the modified electrode showed an electrocatalyt...
full textDevelopment of glassy carbon electrode modified with ruthenium red-multiwalled carbon nanotubes for simultaneous determination of epinephrine and acetaminophen.
A glassy carbon electrode modified with ruthenium red and functionalized multi-walled carbon nanotube has been developed. The electrochemical response characteristics of the modified electrode toward epinephrine (EP) and acetaminophen (AC) was investigated by differential pulse voltammetry (DPV). Linear calibration plots were obtained over the range of 0.3 - 333.3 μM for both EP and AC with sen...
full textVoltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
A glassy carbon electrode modified with a Nafion/MWCNTs composite is shown to enable the determination of codeine using differential pulse voltammetry in phosphate buffer of pH 3.0. At a preconcentration time of 15 s, the calibration graph is linear in the 0.5 µM (0.15 mg·L(-1)) to 15 µM (4.5 mg·L(-1)) concentration range with a correlation coefficient of 0.998. The detection limit at a preconc...
full textMy Resources
Journal title
volume 9 issue 2
pages 190- 201
publication date 2019-04-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023