Simple and Sensitive Method of Fluorometry for Determination of Total Antioxidant Capacity

Authors

  • Bahram Yaghmaie Department of Clinical Biochemistry, Faculty of Medicine, Shahid Beheshti University of Medical Science, Tehran, Iran
  • Mehdi Hedayati Cellular and Molecular Endocrinology Research Center, Institute of Endocrine Sciences, Shahid Beheshti University of Medical Science, Tehran, Iran
  • Saeed Nazeri Department of Clinical Biochemistry, Faculty of Medicine, Shahid Beheshti University of Medical Science, Tehran, Iran
Abstract:

Background and Objective: Oxidative stress plays an important role in the pathogensis of various diseases, including lung cancer, chronic obstructive pulmonary disease, and atherosclerosis. Total antioxidant capacity plays a significant role in the body’s antioxidant defense, so its assessment is a matter of the utmost importance. Currently, assessment of this capacity is performed in various scientific fields by expensive imported kits. The aim of the present study was to design a sensitive fluorometric method for the assessment of total antioxidant capacity and improvement of sensitivity, accuracy, and speed of the measurement. Methods: The sensitivity and intra- and inter-assay accuracy, verification by recovery and parallelism tests, method comparison, and correlation and coherence evaluation were performed. To increase the accuracy and speed of reading, the assay was performed in a microplate and reading was done using a fluorometer plate. Results: In accuracy assessment, intra- and inter-assay coefficient of variation was calculated to be 4.1-5.7 and 4.4-7.5, respectively. In validity evaluation, the recovery percentage was calculated to be 90-109, the recovery percentage range was 90 to 109. Comparison of the results of this method on 50 serum samples with common colorimetric method, indicated a good correlation (0.93). The sensitivity of the studied method was 0.01 mM/l. Conclusion: Microplate-reader fluorometry, in addition to increasing the speed of measurement, has enough efficacy, accuracy, and sensitivity to assess total antioxidant capacity and could be  an appropriate alternative for current colorimetric methods.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

simple and sensitive method of fluorometry for determination of total antioxidant capacity

background and objective: oxidative stress plays an important role in the pathogensis of various diseases, including lung cancer, chronic obstructive pulmonary disease, and atherosclerosis. total antioxidant capacity plays a significant role in the body’s antioxidant defense, so its assessment is a matter of the utmost importance. currently, assessment of this capacity is performed in various s...

full text

Comparison of Prooxidant-antioxidant Balance Method with Crocin Method for Determination of Total Prooxidant-antioxidant Capacity

Objective(s) Comparison of prooxidant-antioxidant balance (PAB) assay with crocin assay. Materials and Methods Twenty eight serum samples were chosen, PAB and the total antioxidant capacity were measured by PAB assay and crocin, respectively, and the correlation of both assays, along with their correlation with other clinical and biochemical parameters, were determined. Results A significa...

full text

comparison of prooxidant-antioxidant balance method with crocin method for determination of total prooxidant-antioxidant capacity

objective(s) comparison of prooxidant-antioxidant balance (pab) assay with crocin assay. materials and methods twenty eight serum samples were chosen, pab and the total antioxidant capacity were measured by pab assay and crocin, respectively, and the correlation of both assays, along with their correlation with other clinical and biochemical parameters, were determined. results a significant ne...

full text

the innovation of a statistical model to estimate dependable rainfall (dr) and develop it for determination and classification of drought and wet years of iran

آب حاصل از بارش منبع تأمین نیازهای بی شمار جانداران به ویژه انسان است و هرگونه کاهش در کم و کیف آن مستقیماً حیات موجودات زنده را تحت تأثیر منفی قرار می دهد. نوسان سال به سال بارش از ویژگی های اساسی و بسیار مهم بارش های سالانه ایران محسوب می شود که آثار زیان بار آن در تمام عرصه های اقتصادی، اجتماعی و حتی سیاسی- امنیتی به نحوی منعکس می شود. چون میزان آب ناشی از بارش یکی از مولفه های اصلی برنامه ...

15 صفحه اول

Determination of Total Antioxidant Capacity in Saliva of Smokers and Non-smokers with Chronic Periodontitis

Background: Periodontal diseases in smokers are 2.6 to 6 times higher than non-smokers and their response to treatment is much lower. Reducing levels of antioxidants and consequently increasing oxidative damage in the pathogenesis of periodontitis is effective. Regarding the importance of free radicals in the pathogenesis of periodontal diseases, the aim of this study was to investigate the eff...

full text

Development of a Simple and Sensitive Terbium Sensitized Fluorescence Method for Determination of Epinephrine and Norepinephrine in Serum

     A simple, rapid, selective and highly sensitive fluorimetric method for determination of two catecholamines, i.e. norepinephrine (NE) and epinephrine (EP), in serum samples was developed. The method is based on the fluorescence sensitization of terbium (Tb3+) by complexation with both catecholamines in the presence of lanthanum (La3+), as a co-cation, and in a Na...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 1  issue None

pages  29- 35

publication date 2017-04

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023