Signal Intensity of High B-value Diffusion-weighted Imaging for the Detection of Prostate Cancer
Authors
Abstract:
Background: Diffusion-weighted imaging (DWI) is a main component of multiparametric MRI for prostate cancer detection. Recently, high b value DWI has gained more attention because of its capability for tumor characterization. Objective: To assess based on histopathological findings of transrectal ultrasound (TRUS)-guided prostate biopsy as a reference, an increase in signal intensity of prostatic lesions in comparison with normal background tissue on high b-value diffusion-weighted images could be a sign of malignancy. Material and Methods: Fifty-three consecutive patients retrospectively included in the study. All patients underwent routine TRUS-guided prostate biopsies involving 12 cores after the magnetic resonance imaging (MRI) examinations. In seventeen patients (n =35 lesions), the prostate cancer was histologically confirmed by TRUS-guided prostate biopsy. The biopsy results of other patients were negative. Signal intensities on the high b-value (1600 s/mm2) images of the peripheral zone, the central gland, and the defined lesions were evaluated using region of interest-based measurements. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for prostate cancer detection using signal intensity of high b value diffusion-weighted images were calculated. Results: In the patients with confirmed prostate cancer, fourteen had visually increased SI on the high b-value images. The SI of lesions for these patients was higher than the SI of peripheral zone (22±18%) or central gland (31±20%). In patients with a negative biopsy, eight had visually increased SI on the high b-value images. The SI of lesions for these patients was 23±21% and 35±18% higher than the SI in the peripheral zone and the central gland, respectively. The sensitivity, specificity, PPV, and NPV for prostate cancer using SI of high b value DWI were 71, 87, 62, and 87 %, respectively. Conclusion: Visually increased SI on the high b-value images can be an indication of malignancy, although some benign lesions also show this increase in signal intensity.
similar resources
Accuracy of high b-value diffusion-weighted MRI for prostate cancer detection: a meta-analysis.
Background The diagnostic accuracy of diffusion-weighted imaging (DWI) to detect prostate cancer is well-established. DWI provides visual as well as quantitative means of detecting tumor, the apparent diffusion coefficient (ADC). Recently higher b-values have been used to improve DWI's diagnostic performance. Purpose To determine the diagnostic performance of high b-value DWI at detecting prost...
full textDiffusion-Weighted Magnetic Resonance Imaging for the Evaluation of Prostate Cancer: Optimal B Value at 3T
OBJECTIVE To retrospectively determine the optimal b value of diffusion-weighted imaging (DWI) for predicting the presence of localized prostate cancer, and to evaluate the utility of DWI under different b values in differentiating between cancers and benign prostatic tissues. MATERIALS AND METHODS Eighty patients with suspected prostate cancer underwent MRI including DWI at 3T, followed by r...
full textDiffusion-weighted imaging with relative signal intensity statistical thresholding for delineating prostate cancer tumors.
PURPOSE We assessed the utility of diffusion-weighted imaging (DWI) with relative signal intensity (rSI) statistical thresholding for delineating prostate cancer tumors. MATERIALS AND METHODS Seventeen patients with prostate cancer underwent DWI before total prostatectomy. We measured standard deviation (SD) of the signal intensity (SI) of the lesser pelvic space at DWI, created rSI maps, dis...
full textQuantitative evaluation of computed high B value diffusion-weighted magnetic resonance imaging of the prostate.
OBJECTIVES Computed diffusion-weighted magnetic resonance imaging (cDWI) refers to the synthesizing of arbitrary b value diffusion-weighted images (DWI) from a set of measured b value images by voxelwise fitting. The objectives of this study were to quantitatively analyze the noise and the contrast-to-noise ratio (CNR) in cDWI as a function of b value by numerical simulations and by measurement...
full textSignal to noise ratio of high b-value diffusion weighted images is improved using computed diffusion weighted imaging
acquired (+) and computed DWI imaging (x) where the acquisition time is kept the same for both. It is seen that noise remains constant across b-values for the conventionally acquired images whereas for cDWI it reduces with b-value as predicted by equation 1 (dotted curve). It is seen that for high b-values (>700 s mm) the SNR of cDWI is improved compared to conventional imaging. Figure 1. An ex...
full textImproved detection of heat stroke-induced brain injury by high b-value diffusion-weighted imaging.
We report a case of heat stroke in which detection of brain injury was improved by high b-value diffusion-weighted imaging (DWI). High b-value DWI revealed moderate to marked hyperintensity at/around bilateral dentate nuclei and part of thalami. Apparent diffusion coefficient maps revealed apparent diffusion coefficient decrease of the dentate lesions. Routine DWI showed only mild hyperintensit...