Shot Peening as an Alternative to Fatigue Life Improvement of CK45 Steel Coated with an Electroless Ni-Cu-P
Authors
Abstract:
The effect of an electroless Ni-Cu-P coating on the fatigue behavior of quenched and tempered CK45 steel has been investigated. The fatigue tests under rotating bending conditions have been conducted in three different conditions of uncoated, as-deposited and shot peened prior to the coating deposition. The results indicate that plating of the base steel leads to a fatigue life reduction. The decrease in the fatigue strength was observed to be less marked for the shot peened specimens. The microscopic observations indicate that in the as-deposited condition, the reduction in fatigue life is associated with the nucleation of fatigue cracks on the lateral side of coating. On the contrary, when the samples were shot peened prior to the coating deposition, the crack initiation sites were displaced to the coating-substrate interface which led to an improvement of fatigue behaviour
similar resources
shot peening as an alternative to fatigue life improvement of ck45 steel coated with an electroless ni-cu-p
the effect of an electroless ni-cu-p coating on the fatigue behavior of quenched and tempered ck45 steel has been investigated. the fatigue tests under rotating bending conditions have been conducted in three different conditions of uncoated, as-deposited and shot peened prior to the coating deposition. the results indicate that plating of the base steel leads to a fatigue life reduction. the d...
full textSide Effects of Shot Peening on Fatigue Crack Initiation Life
Shot peening beneficial effects on fatigue life of mechanical components are well known. However, there are some reports in the literature that indicate inappropriate shot peening parameters tend to reduce the fatigue life. It is therefore, the purpose of this study to find a logical quantitative justification for these observations. Using finite element method, a dynamic elastic-plastic simula...
full textEffects of Pretreatment Prior to Electroless Ni-P Plating on Fatigue Behavior of SAE 1045 Steel
Electroless Ni-P (EN) plating, as an important group of metallic coatings, employed in a wide range of industrial applications. The current work aims to investigate the effects of pretreatment process before EN plating on fatigue behavior of SAE 1045 steel. The specimens of rotating bending fatigue test were prepared from the steel in two series. A group of samples used in as-polished con...
full textInvestigating Tribological Characteristics of Ni-P and Double–Layered Ni-P/Ni-B Electroless Coatings Applied to the Carbon Mild Steel Ck45
In this research, tribological characteristics of Ni-P electroless coating and double-layered Ni-P/Ni-B electroless coating were studied. For this purpose, Ni-P electroless coating with 25 μm thickness was initially applied to the surface of steel Ck45 samples; then, a double-layered Ni-P/Ni-B electroless coating, including inner layer of Ni-P with 15 μm thickness and outer layer of Ni-B with 1...
full textStudy and Simulation of Shot peening Effect on Fatigue Life of a Powder Forged Connecting rod
Shot peening applies a residual compressive stress field (RCSF) on the surface of parts. It also shifts “crack nucleation sites” to sub-surface locations. A nondestructive method of measuring the stresses, Sin2ψ was utilized here and the stress values introduced to Ansys software. For this purpose, uniform stress in all directions was applied on the con rod. Loading on the rod in Ansys had thre...
full textinvestigating tribological characteristics of ni-p and double–layered ni-p/ni-b electroless coatings applied to the carbon mild steel ck45
in this research, tribological characteristics of ni-p electroless coating and double-layered ni-p/ni-b electroless coating were studied. for this purpose, ni-p electroless coating with 25 μm thickness was initially applied to the surface of steel ck45 samples; then, a double-layered ni-p/ni-b electroless coating, including inner layer of ni-p with 15 μm thickness and outer layer of ni-b with 1...
full textMy Resources
Journal title
volume 2 issue 1
pages 1- 6
publication date 2005-06-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023