Sensitivity Analysis of Frequency Response of Atomic Force Microscopy in Liquid Environment on Cantilever's Geometrical Parameters

author

  • M. Damircheli Assistant professor, Department of Mechanical Engineering, Shahr-e-Qods Branch, Islamic Azad University, Tehran, Iran
Abstract:

In this paper, the non-linear dynamic response of rectangular atomic force microscopy in tapping mode is considered. The effect of cantilever’s geometrical parameters (e.g., cantilever length, width, thickness, tip length and the angle between the cantilever and the sample's surface in liquid environment has been studied by taking into account the interaction forces. Results indicate that the resonant frequency, amplitude and phase are very sensitive to changes of geometrical parameters. In order to improve and optimize the system's behavior, the sensitive analysis (SA) of geometrical parameters on the first resonant frequency and amplitude of cantilever's vertical displacement has been conducted using Sobol's method. Results show that the influence of each geometrical variable on frequency response of the system can play a crucial role in designing the optimum cantilever in liquid medium for soft and sensitive biological samples. Also, one way to speed up the imaging process is to use short cantilevers. For short beams, the Timoshenko model seems to be more accurate compared to other models such as the Euler-Bernoulli. By using the Timoshenko beam model, the effects of rotational inertia and shear deformation are taken into consideration. In this paper, this model has been used to obtain more accurate results

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Bimodal frequency-modulated atomic force microscopy with small cantilevers.

Small cantilevers with ultra-high resonant frequencies (1-3 MHz) have paved the way for high-speed atomic force microscopy. However, their potential for multi-frequency atomic force microscopy is unexplored. Because small cantilevers have small spring constants but large resonant frequencies, they are well-suited for the characterisation of delicate specimens with high imaging rates. We demonst...

full text

High-frequency response of atomic-force microscope cantilevers

frequency response of atomic-force microscope cantilevers" (1997). Faculty Publications from the Department of Engineering Mechanics. Paper 2. Recent advances in atomic-force microscopy have moved beyond the original quasistatic implementation into a fully dynamic regime in which the atomic-force microscope cantilever is in contact with an insonified sample. The resulting dynamical system is co...

full text

Preamplifying cantilevers for dynamic atomic force microscopy

A cantilever type has been developed for dynamic force microscopy by the addition of a harmonic oscillator in the form of a paddle to atomic force microscopy cantilevers. These cantilevers provide resonant amplification of periodic interactions between the probe and the substrate when the laser is aligned on the paddle. The cantilevers were explored for their use in piezoresponse force microsco...

full text

Atomic-resolution imaging in liquid by frequency modulation atomic force microscopy using small cantilevers with megahertz-order resonance frequencies.

In this study, we have investigated the performance of liquid-environment FM-AFM with various cantilevers having different dimensions from theoretical and experimental aspects. The results show that reduction of the cantilever dimensions provides improvement in the minimum detectable force as long as the tip height is sufficiently long compared with the width of the cantilever. However, we also...

full text

Multiple impact regimes in liquid environment dynamic atomic force microscopy

A canonical assumption in dynamic atomic force microscopy is that the probe tip interacts with the sample once per oscillation cycle. We show this key ansatz breaks down for soft cantilevers in liquid environments. Such probes exhibit “drum roll” like dynamics with sequential bifurcations between oscillations with single, double, and triple impacts that can be clearly identified in the phase of...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 8  issue 4

pages  221- 237

publication date 2016-02-20

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023