Sensitive Simultaneous Measurement of Metformin and Linagliptin in Plasma Samples by Couple of Nano Graphene Oxide-based Dispersive Solid Phase Extraction Method and Liquid Chromatography

Authors

  • Ali Gholami Department of Analytical Chemistry, Faculty of Science, University of Kashan, Kashan, Iran.
  • Fahimeh Bahrami Department of Analytical Chemistry, Faculty of Science, University of Kashan, Kashan, Iran.
  • Mohammad Faraji Department of Food Science and Technology, Faculty of Food Industry and Agriculture, Standard Research Institute (SRI), Karaj, Iran.
Abstract:

A simple, rapid, and ultra sensitive dispersive solid phase extraction based on nano graphene oxide was developed for simultaneous measurement of trace amounts of metformin (MET) and linagliptin (LIN) in plasma samples by HPLC-UV-Vis. Affecting factors on the extraction of these drugs, including adsorbent weight, extraction time, organic solvent type, desorption situations, and composition of solvent were examined and optimized. In optimum conditions, the LOD (limit of detection) and LOQ (limit of quantification) of the suggested technique were 2.0 ngmL-1 and 6.1 (ngmL-1) for LIN and 3.0 ngmL-1 and 9.2 ngmL-1 for MET, respectively. Suitable linear behavior in the considered ranges of concentration (10-2000 ngmL-1) and good correlation coefficient of 0.9901 and 0.9903 (r2) for LIN and MET were obtained, respectively. The RSD (relative standard deviations) according to three replicate measurements at 2, 20, 200 ngmL-1 levels of these drugs was less than 8.0%. In the last step, applicability of the suggested technique was examined by analyzing the drugs in plasma samples and reasonable results were achieved.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Graphene oxide-based dispersive-solid phase extraction for preconcentration and determination of ampicillin sodium and clindamycin hydrochloride antibiotics in environmental water samples followed by HPLC-UV detection

In the present study, a reusable graphene oxide (GO) based dispersive-solid phase extraction (d-SPE) was synthesized and applied for the analysis of trace ampicillin sodium (AMP) and clindamycin hydrochloride (CLI) in water samples followed by high performance liquid chromatography-UV detection (HPLC-UV). Batch experiments were conducted to investigate the effects of pH and volume of the sample...

full text

Graphene oxide-based dispersive-solid phase extraction for preconcentration and determination of ampicillin sodium and clindamycin hydrochloride antibiotics in environmental water samples followed by HPLC-UV detection

In the present study, a reusable graphene oxide (GO) based dispersive-solid phase extraction (d-SPE) was synthesized and applied for the analysis of trace ampicillin sodium (AMP) and clindamycin hydrochloride (CLI) in water samples followed by high performance liquid chromatography-UV detection (HPLC-UV). Batch experiments were conducted to investigate the effects of pH and volume of the sample...

full text

Solid Phase Extraction Using Modified Magnetic Iron Oxide Nanoparticles for Extraction and Spectrofluorimetric Determination of Carvedilol in Human Plasma Samples

A new analytical approach was developed involving magnetic solid–phase extraction and spectrofluorimetric determination of carvedilol in human plasma samples. A plasma sample was prepared and adjusted to pH 8.2–10, then carvedilol was quickly extracted using iron oxide magnetic nanoparticles modified by the surfactant cetyltrimethylammonium bromide and determined to apply spectrofluorimetry...

full text

extraction and characterization of allium irancum plant extract and its application in the green synthesis of silver nano particles and oxidation of thiocarbony1 compounds

سنتز سبز نانوذرات فلزی (nps) درسالهای اخیر توجه بسیارزیادی را به خود جلب کرده است. زیرا این پروتوکل کم هزینه وسازگار با محیط زیست از روش های استاندارد سنتز. در این پایان نامه ما گزارش میکنیم یک روش ساده و سازگار با محیط زیست برای سنتز نانوذرات نقره با استفاده از محلول آبی عصاره گیاه allium iranicum به عنوان یک عامل کاهش دهنده ی طبیعی. نانو ذرات نقره مشخص شد با استفاده از تکنیک های uv-visible، x...

Preconcentration and Determination of Mefenamic Acid in Pharmaceutical and Biological Fluid Samples by Polymer-grafted Silica Gel Solid-phase Extraction Following High Performance Liquid Chromatography

Abstract Mefenamic acid is a nonsteroidal anti-inflammatory drug (NSAID) that has analgesic,anti-infammatory and antipyretic actions. It is used to relieve mild to moderate pains. Solid-phase extraction of mefenamic acid by a polymer grafted to silica gel is reported . Poly allyl glycidyl ether/iminodiacetic acid-co-N, N-dimethylacrylamide was synthesized and grafted to silica gel and was used ...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 19  issue 2

pages  274- 282

publication date 2020-06-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023