Respiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation

Authors

  • Ahmad Bitarafan rajabi Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, IR
  • Khadijeh Bamneshin Iran University of Medical Science, Tehran, Iran
  • Parham Geramifar Asisstant Professor, Tehran University of Medical Sciences
  • Seied Mohsen Shahabi Shadi Beheshti of Medicai Science, Tehran, Iran
Abstract:

Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motions using the 4D NCAT phantom. Lesions with different activities and diameters were simulated in prostate. This study was conducted in two phases. In the first phase; the generated PET sinograms taken from GATE (Geant4 Application Tomography Emission) Monte Carlo simulations corrected using computed tomography attenuation correction involving the cycle. In the next phase; on the obtained images, the motion-correction was carried out using software for Tomographic Image Reconstruction (STIR). By considering respiration- averaged computed as a true value, the SUVs were measured and analyzed for different motions. Results: In uncorrected measurements, the mean, minimum and maximum SUVs were 0.4%, 0.09% and 2% respectively, whilst in corrected measurements, these value were reported as 3.5%, 0.7% and 14% respectively. Conclusion: The respiratory motion-induced errors in tumor quantification and delineation. The SUVs depending on the phase of the raspatory. Motion correction could enhance the SUVs in prostate cancer PET.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Respiratory Motion Correction in Positron Emission Tomography

In this thesis, we develop a motion correction method to overcome the degradation of image quality introduced by respiratory motion in positron emission tomography (PET), so that diagnostic performance for lung cancer can be improved. Lung cancer is currently the most common cause of cancer death both in the UK and in the world. PET/CT, which is a combination of PET and CT, providing clinicians...

full text

Imaging Cellular Proliferation in Prostate Cancer with Positron Emission Tomography

Prostate cancer remains a major public health problem worldwide. Imaging plays an important role in the assessment of disease at all its clinical phases, including staging, restaging after definitive therapy, evaluation of therapy response, and prognostication. Positron emission tomography with a number of biologically targeted radiotracers has been demonstrated to have potential diagnostic and...

full text

Background-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study

Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...

full text

a study on rate making and required reserves determination in reinsurance market: a simulation

reinsurance is widely recognized as an important instrument in the capital management of an insurance company as well as its risk management tool. this thesis is intended to determine premium rates for different types of reinsurance policies. also, given the fact that the reinsurance coverage of every company depends upon its reserves, so different types of reserves and the method of their calc...

Respiratory Motion Correction in Emission Tomography Imaging

During an emission tomography exam of lungs, respiratory motion blurs the reconstructed image, which may lead to misinterpretations and imprecise diagnosis. Solutions like respiratory gating, correlated dynamic PET techniques, listmode data based techniques and others have been tested with improvements over the spatial activity distribution in lungs lesions, but with the disadvantages of either...

full text

background-based delineation of internal tumor volumes on static positron emission tomography in a phantom study

objective(s): considering the fact that the standardized uptake value (suv) of a normal lung tissue is expressed as x±sd, x+3×sd could be considered as the threshold value to outline the internal tumor volume (itv) of a lung neoplasm. methods: three hollow models were filled with 55.0 kbq/ml fluorine18- fluorodeoxyglucose (18f-fdg) to represent tumors. the models were fixed to a barrel filled w...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  22- 22

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023