Radiomics modelling of IMRT induced acute rectal toxicity using clinical and magnetic resonance imaging features

Authors

  • Abolfazl Razzaghdoust Urology and Nephrology Research Center, Student Research Committee, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  • Afshin Sadipour Department of Radiation Oncology, Shohada Tajrish Medical Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  • Bahram Mofid Department of Radiation Oncology, Shohada Tajrish Medical Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  • Hamid Abdollahi Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
  • Mohsen Bakhshandeh Department of Radiology Technology, Allied Medicine Faculty, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  • Seied Rabi Mahdavi Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran Radiation Biology Research Center, Iran University of Medical Sciences, Tehran, Iran
  • Shayan Mostafaei Department of Community Medicine, Faculty of Medicine, Kermanshah University of Medical Sciences, Kermanshah, Iran. Epidemiology and Biostatistics Unit, Rheumatology Research Center, Tehran University of Medical Sciences, Tehran, Iran.
Abstract:

Introduction: Rectal toxicity is a dose limiting issue in prostate cancer radiotherapy. Prediction of these effects may be used to tailor the therapy. The purpose of this work was to develop predictive radiomic models based on clinical, dosimetric and radiomic features extracted from rectal wall magnetic resonance image (MRI).   Materials and Methods: This study was conducted on 30 prostate cancer patients underwent intensity modulated radiation therapy (IMRT). Patient’s clinical and dosimetric parameters were collected and proctitis was assessed. All patients underwent MRI before and after IMRT with same protocol. Several radiomic features were extracted from rectal wall MR images including T2 weighted (T2W) and apparent diffusion coefficient (ADC) scans and robust features were found. Lasso regularization was used to create multivariable Elastic Net logistic regression model, based on clinical, dosimetric and robust features for prediction and feature selection, simultaneously. All models were cross-validated using repeated five-fold cross-validation and their performance were evaluated by area under the curve of the ROC curve (AUC), sensitivity and specificity.   Results: Eleven predictive models including one clinical and ten radiomic models were built. All models were found as high predictive performance (AUC≥0.83). T2 based radiomic models were more predictive rather than ADC models. Post-IMRT T2W radiomic model also showed a good predictive performance. Image features enhanced the all model’s predictive performance.   Conclusion: Rectal wall MR radiomic features integrating with clinical and dose-volume parameters could improve the prediction performance of radiotherapy induced proctitis. The authors have demonstrated the performance of radiomic features extracted from pre IMRT T2W and ADC MR Images for prediction of IMRT induced rectal toxicity. These results may be used to tailor the therapy in terms of patient and.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

synthesis of amido alkylnaphthols using nano-magnetic particles and surfactants

we used dbsa and nano-magnetic for the synthesis of amido alkylnaphtols.

15 صفحه اول

Measurement of Posterior Tibial Slope Using Magnetic Resonance Imaging

Background: Posterior tibial slope (PTS) is an important factor in the knee joint biomechanics and one of the bone features, which leads to knee joint stability. Posterior tibial slope affects flexion gap, knee joint stability and posterior femoral rollback that are related to wide range of knee motion. During high tibial osteotomy and total knee arthroplasty (TKA) surgery, proper retaining the...

full text

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

full text

Magnetic resonance imaging of feline eye

The purpose of this study was to investigate magnetic resonance imaging (MRI) of the normal feline eyeand optic nerves using T1-weighted and T2-weighted images. A total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. Magnetic resonance imaging data werecollected using GEMSOW (Philips) at a magnetic field strength of 1.5 T. Dorsal, sagittal, a...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  340- 340

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023