Radiologic Assessment of Distal Femur Cutting Angle in Varus Knee Candidates for Total Knee Arthroplasty
Authors
Abstract:
Background: In a total knee arthroplasty surgery the goal is to produce 90 degree angle between the knee articular lobe and the mechanical femoral line. Most orthopedic surgeons usually utilize a 5 to 7 degree for distal femoral cutting angle. In this study we will aim at clearing this question, that whether the” five-seven degree” distal femoral cutting angle supposed to be an equable spectrum? Method: In this three year course of study, 123 candidate patients for knee arthroplasty with varus knee deformities underwent pre operatore radiologic assessment before joint replacement surgery. The femoral bowing angle, distal femoral cutting angle, neck shaft angle, angle between knee articular line and mechanical femoral angle were assessed and statistically analyzed. Results: The mean varus angle was in 13.71±4.34 in male and 16.41±7.87 in female. The mean distal femoral cutting angle (DFCA) was 6.50±1.09 in male and 7.38±1.75 in female. In 48 patients (%39) the female DFCA was out of 507 degree range. In 32 (26%) of patients the DFCA was 7-9 degrees and in 8 (%6) it was over 9 degrees, and in 8 (%6) was less than 5. The angle differences had no sex-related variation. There was a good co-relation between DFCA and bowing angle (r=0.769). The co-relation between DFCA and NSA was moderator (r=0.523). The co-relation between DFCA and DFA (r=0.11) and varus angle with LDFA (r=0.28) was low. LDFA was also related to NSA (r=0.15). Therefore, the candidates for knee replacement who have varus deformity may need a distal femoral cutting angle over 7 degrees. Based on these results, the distal femoral cutting angle in patients in need of a knee arthroplasty and varus deformity might be more than seven degrees. Conclusion: The distul femoral cutting angle in knee arthroplasty in face of severe varus does not have a constant value and maybe over 7 degrees. A long standing radiograph is needed to measure the mechanical and correlate with axis the anatomic axis of distal third of femur. When the bowing angle is high the DFCA will need to be higher.
similar resources
DIFFERENT REFERENCES FOR VALGUS CUT ANGLE IN TOTAL KNEE ARTHROPLASTY
This was Presented in 5th International congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran
full textDifferent References for Valgus Cut Angle in Total Knee Arthroplasty
Background: The valgus cut angle (VCA) of the distal femur in Total Knee Arthroplasty (TKA) is measured preoperativelyon three-joint alignment radiographs. The anatomical axis of the femur can be described as the anatomical axis of thefull length of the femur or as the anatomical axis of the distal half of the femur, which may result in different anglesin some cases. During TKA, the anatomical ...
full textAnthropometric Measurements of Distal Femur to Design the Femoral Component of Total Knee Arthroplasty for the Iranian Population
Background: Acquiring knowledge about anatomic and geometric quantities of bones is among the most vitalparameters in orthopedic surgery that has a significant effect on the treatment of various disorders and subsequentoutcomes. The aim of this study was to obtain anthropometric information for distal femur in order to compare withsimilar dimensions of prosthesis used in total...
full textconversion of fused knee following distal femur tumor surgery to total knee arthroplasty
conversion of knee arthrodesis to total knee arthroplasty is a difficult procedure accompanied by many complications due to soft tissue and extensor mechanism contracture and bone defects. we report two cases of distal femur osteosarcoma that had been undergone wide resection arthrodesis initially. arthrodesis was converted to total knee arthroplasty with hinged prosthesis after many years. we ...
full textFemur positioning in navigated total knee arthroplasty.
Navigated total knee arthroplasty (TKA) results in better restoration of neutral mechanical axis than does the conventional technique. Nevertheless, coronal malalignment has not been eliminated. It is yet unknown whether errors in implant positioning occur more on the femoral side, more on the tibial side, or equally on both sides. The hypothesis of this study was that a predominance of coronal...
full textConversion of Fused Knee Following Distal Femur Tumor Surgery to Total Knee Arthroplasty
Conversion of knee arthrodesis to total knee arthroplasty is a difficult procedure accompanied by many complications due to soft tissue and extensor mechanism contracture and bone defects. We report two cases of distal femur osteosarcoma that had been undergone wide resection arthrodesis initially. Arthrodesis was converted to total knee arthroplasty with hinged prosthesis after many years. We ...
full textMy Resources
Journal title
volume 16 issue 4
pages 272- 275
publication date 2018-12
By following a journal you will be notified via email when a new issue of this journal is published.
No Keywords
Hosted on Doprax cloud platform doprax.com