Radiographic Comparison of Crestal Bone Loss Around Two Implant Systems with Different Surface Roughness: A Retrospective Study

Authors

  • Hanane Pourheidary Dental Student, Faculty of Dentistry, Shahed University, Tehran, Iran
  • Sayed Shojaedin Shayegh Shayegh Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Shahed University, Tehran, Iran
  • Shahriar Shahab Assistant Professor, Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Shahed University, Tehran, Iran
Abstract:

Background and Aim: This retrospective study aimed to investigate the effects of surface roughness and implant body design on the amount of crestal bone loss around implant. Materials and Methods: In this retrospective study, dental records of 87 patients who received 139 implants were evaluated. The ITI group received 63 implants with moderate roughness, while the DIO group received 76 implants with hybrid rough-ness. Radiographs were taken immediately after implant placement, on the day of loading of the prosthesis, and 1 and 2 years after loading by using the parallel method. The Mann-Whitney U test was used to compare bone loss in the two groups at different time points, and the Wilcoxon test was used to evaluate the intra-group variations during a period of 1-2 years after applying the force (P=0.05). Results: Radiographic records of 23 implants (16%) were unavailable during the sec-ond year. The ITI group had more bone loss at all three time points. Marginal bone loss in the ITI group during the second year was 0.65±0.44 mm and was significantly more than that in the DIO group (0.28±0.16 mm; P<0.05). The mean bone loss during the time interval of the first to the second year was significantly less than the bone loss during the time interval of loading to the first year (P<0.05) in both groups. Conclusion: Based on the failure criteria, none of the implants failed after 2 years of loading. Implants with hybrid surface roughness were superior in preserving the mar-ginal bone around implants against occlusal forces.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Crestal bone changes around titanium implants. Part I: A retrospective radiographic evaluation in humans comparing two non-submerged implant designs with different machined collar lengths.

BACKGROUND Experimental studies demonstrated that peri-implant crestal hard and soft tissues are significantly influenced in their apico-coronal position by the rough/smooth implant border as well as the microgap/ interface between implant and abutment/restoration. The aim of this study was to evaluate radiographically the crestal bone level changes around two types of implants, one with a 2.8 ...

full text

Changes in crestal bone around endosseous implants during functional loading: a radiographic evaluation in edentulous patients comparing different implant designs.

Marginal bone changes around titanium plasma-sprayed implants (n = 240) placed in the mandibular interforaminal regions of 120 edentulous patients were assessed over 5 years of follow-up, with emphasis on the influence of the locations of the microgap and rough/smooth border. Marginal bone changes were measured on standardized radiographs. Locations of the microgap and the rough/smooth border w...

full text

Crestal bone changes around titanium implants: a methodologic study comparing linear radiographic with histometric measurements.

Generally, endosseous implants can be placed according to a nonsubmerged or a submerged technique and in 1-piece or 2-piece configurations. Recently, it has been shown that peri-implant crestal bone reactions differ significantly radiographically as well as histometrically under such conditions and are dependent on a rough/smooth implant border in 1-piece implants and on the location of a micro...

full text

Peri-Implant Crestal Bone Loss: A Putative Mechanism

Purpose. The immunological mechanisms of peri-implant crestal bone loss have, hitherto, not been elucidated. We hypothesized that bacterial products from the microgap cause upregulation of cytokines in otherwise healthy peri-implant cells, which results in osteoclast formation and, ultimately, in bone resorption. Materials and Methods. We used RT-PCR and ELISA to assay mediators of osteoclastog...

full text

Influence of flap design on peri-implant interproximal crestal bone loss around single-tooth implants.

The anterior maxilla represents a therapeutic challenge for single-tooth replacement with implants. The surgical trauma delivered to soft and hard tissues during implant placement can influence the future esthetic result. The clinician should use surgical techniques that prevent esthetic complications, such as increased crown length or loss of interdental papillae, without compromising osseoint...

full text

Crestal Bone Loss Around Dental Implants; A Short Communication

Many studies described several parameters which are supposed to determine success or failure in longterm evaluations of dental implants. However, the relationship between crestal bone loss around implants and the location of implant-abutment connection in the bone still needs further investigations.The subgingival microgap between the implant and the abutment, which creates higher bone level re...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 31  issue 3

pages  162- 168

publication date 2019-07

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023