Radiation exposure from diagnostic nuclear medicine examinations in Golestan province

Authors

  • Ali Asghar Parach Department of Medical Physics, Shahid Sadoughi University of Medical Sciences,Yazd, Iran
  • Ali Mahmoud Pashazadeh The Persian Gulf Nuclear Medicine Research Center, Bushehr University of Medical Sciences, Bushehr, Iran
  • Faraj Tabei Department of Nuclear Medicine, Taleghani Hospital, Shahid Beheshti University of Medical Science, Tehran, Iran AND Department of Medical Physics & Engineering, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  • Hamid Javadi Golestan Research Center of Gastroenterology and Hepatology, Golestan University of Medical Sciences, Gorgan, Iran
  • Isa Neshandar Asli Department of Nuclear Medicine, Taleghani Hospital, Shahid Beheshti University of Medical Science, Tehran, Iran
  • Majid Assadi The Persian Gulf Nuclear Medicine Research Center, Bushehr University of Medical Sciences, Bushehr, Iran
  • Mehdi Mogharrabi Department of Nuclear Medicine, 5th Azar Hospital, Golestan University of Medical Sciences, Gorgan, Iran
Abstract:

Introduction: The aim of present study was to estimate effective dose from most common procedures performed in nuclear medicine departments of Golestan province. Methods: Data of nuclear medicine procedures performed in 2 nuclear medicine departments in Golestan province were collected during 4 years. Effective dose, collective effective dose and effective dose per examination were calculated using standard dosimetry tables. Results: Based on the data of this study, results of 10437 nuclear medicine procedures performed during 4 years have lead to 3.97 mSv as average effective dose per examination and 10.37 human-Sv as mean collective effective dose. It was also revealed that Tc-99m was the main source of effective dose (98.3%), bone scan was the most common procedure (25.9%) and cardiac scan (MIBI-rest) has the highest collective effective dose (33.5%) during 4 years. Conclusion: Beside the cardiac scan which was the most common nuclear medicine procedure and the main contributor of effective dose in patients, due to geographical condition of the northeast of Iran, bone scan was the highest performed nuclear medicine examination in the Golestan province.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

radiation exposure from diagnostic nuclear medicine examinations in golestan province

introduction: the aim of present study was to estimate effective dose from most common procedures performed in nuclear medicine departments of golestan province. methods: data of nuclear medicine procedures performed in 2 nuclear medicine departments in golestan province were collected during 4 years. effective dose, collective effective dose and effective dose per examination were calculated u...

full text

Radiation Exposure from CT Examinations in Japan

BACKGROUND Computed tomography (CT) is the largest source of medical radiation exposure to the general population, and is considered a potential source of increased cancer risk. The aim of this study was to assess the current situation of CT use in Japan, and to investigate variations in radiation exposure in CT studies among institutions and scanners. METHODS Data-sheets were sent to all 126...

full text

Physician knowledge of nuclear medicine radiation exposure.

PURPOSE Because physician knowledge of patient exposure to ionizing radiation from computed tomography (CT) procedures previously has been recognized as poor, the purpose of this systematic review is to determine whether physician or physician trainee knowledge of patient exposure to radiation from nuclear medicine procedures is similarly insufficient. METHODS Online databases and printed lit...

full text

Occupational Radiation Exposure among the Staff of Departments of Nuclear Medicine and Diagnostic Radiology in Kuwait

OBJECTIVES To investigate radiation exposure among the staff of departments of nuclear medicine (NM) and diagnostic radiology (DR) during 2008 and 2009 and to compare the mean doses received with the limit of 20 mSv/year of the International Commission of Radiological Protection (ICRP). MATERIALS AND METHODS The whole-body dose or effective dose, i.e. Hp(10), and the skin dose, i.e. Hp(0.07),...

full text

Estimating the radiation dose of non-radiation workers from nuclear medicine patients

Introduction: As a valuable imaging modality, Nuclear Medicine (NM) indications is raising in clinical practice. The remained portion administrated radioactive material in patients’ tissues is a critical issue, especially when the procedure is performed in hospitalized patients, where the non-radiation workers present. The aim of this study was evaluation the dose of non-radia...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 21  issue 2

pages  65- 69

publication date 2013-10-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023