Quantification of Polyethylene Glycol Esters of Methotrexate and Determination of Their Partition Coefficients by Validated HPLC Methods

Authors

  • Yousefi Gh
  • A Shafaati
  • SM Foroutan
Abstract:

Conjugation of methotrexate (MTX) (MW 454) with different molecular weights of polyethylene glycol (PEG) including methoxy-peg (mpeg) 750 D and 5000 D and diol-peg 35000 D led to compounds that are physicochemically highly different from the parent compound, MTX. In this study, an HPLC system consisting of C8 column and UV detector (?=342 nm), using a mixture of 30:70 v/v phosphate-citrate buffer (pH 4): methanol mobile phase, was validated for quantification of the esters. Three other HPLC methods using three mixture of buffer phosphate-citrate (pH 6): methanol at 30:70, 40:60 and 50:50 v/v, respectively, was set for estimation of partition coefficients the esters. Eight reference standard materials were selected from literature covering the retention times lower and higher than esters. An identical log P (4.3) was obtained for all three esters, despite their different molecular weights (i.e. 1200, 5500 and 35500 D theoretically). In addition the log P obtained differs from that of the parent drug (-1.4). This high difference comes probably from different ability of drug and esters in ionization of carboxylic acid groups.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

quantification of polyethylene glycol esters of methotrexate and determination of their partition coefficients by validated hplc methods

conjugation of methotrexate (mtx) (mw 454) with different molecular weights of polyethylene glycol (peg) including methoxy-peg (mpeg) 750 d and 5000 d and diol-peg 35000 d led to compounds that are physicochemically highly different from the parent compound, mtx. in this study, an hplc system consisting of c8 column and uv detector (?=342 nm), using a mixture of 30:70 v/v phosphate-citrate buff...

full text

investigation of single-user and multi-user detection methods in mc-cdma systems and comparison of their performances

در این پایان نامه به بررسی روش های آشکارسازی در سیستم های mc-cdma می پردازیم. با توجه به ماهیت آشکارسازی در این سیستم ها، تکنیک های آشکارسازی را می توان به دو دسته ی اصلی تقسیم نمود: آشکارسازی سیگنال ارسالی یک کاربر مطلوب بدون در نظر گرفتن اطلاعاتی در مورد سایر کاربران تداخل کننده که از آن ها به عنوان آشکارساز های تک کاربره یاد می شود و همچنین آشکارسازی سیگنال ارسالی همه ی کاربران فعال موجود در...

development of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles

a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...

determination of olanzapine and thiourea using electrodes modified by dna and film of copper-cobalt hexacyanoferrate & investigation of electro-oxidation of some catechol derivatives in the presence of 4-phenylsemicarbazid

چکیده هدف از این کار بررسی الکترواکسیداسیون کتکول و مشتقات آن در حضور 4-فنیل سمی کاربامازید بوده است اکسیداسیون کتکولها ترکیبات نا پایدار کینونها را تولید می کنند که این ترکیبات می تواند در واکنش مایکل بعنوان پذیرنده نوکلئوفیل عمل نمایند. در ادامه اکسایش کتکولهای (a-c1) را درحضور 4-فنیل سمی کاربامازید در محلول آب/استونیتریل (90/10)بوسیله ولتامتری چرخه ای و کولن متری در پتانسیل ثابت مورد بررسی ...

15 صفحه اول

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume Volume 8  issue Number 1

pages  27- 31

publication date 2010-11-20

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023