Quality Assurance of LINAC by Analyzing the Profile of 6-MV and 10-MV Photon Beams Using Star Track Device
Authors
Abstract:
Introduction: According to the American Society of Radiation Oncology, all patients receive radiation therapy during their illness, where radiation is delivered by the medical linear accelerator (Linac). The aim of this study was to evaluate the quality assurance (QA) of the Linac in analyzing the used dose profile in the treatment of cancer tumors. Material and Methods: This experimental study was performed using Linac (synergy device type) at Baghdad Radiotherapy and Nuclear Medicine laboratories, Baghdad, Iraq. The Star Track device was used for the routine quality assurance of the Linac, using photon beam for the reference Dmax and source to surface distance of 100 cm. The Star Track consists of 453 vented parallel plate ionization chambers. Results: The flatness and symmetry of beams for the reference field size did not exceed from ±2%, as they were within the allowed range. Moreover, the penumbra region showed a change in value that did not exceed from ±0.2 cm. using the Star Track method; maximum differences in beam symmetry and beam flatness were measured at 0.76%±2% and 1.17%±2%, respectively. Moreover, the maximum difference in the penumbra region was estimated at 0.12±0.2 cm. Conclusion: The results indicated, the Star Track could successfully calculate the characteristics of dose profile during a time period of 2,500 ms, showing the superiority of this instrument over other verification devices.
similar resources
Monte Carlo Simulation of Siemens Primus plus Linac for 6 and 18 MV Photon Beams
Objective: The aim of the present study is to simulate 6 MV and 18 MV photon beam energies of a Siemens Primus Plus medical linear accelerator (Linac) and to verify the simulation by comparing the results with the measured data.Methods: The main components of the head of Siemens Primus Plus linac were simulated using MCNPX Monte Carlo (MC) code. To verify the results, experimental data of perce...
full textMonte Carlo Simulation of Siemens Primus plus Linac for 6 and 18 MV Photon Beams
Objective The aim of the present study is to simulate 6 MV and 18 MV photon beam energies of a Siemens Primus Plus medical linear accelerator (Linac) and to verify the simulation by comparing the results with the measured data. Methods The main components of the head of Siemens Primus Plus linac were simulated using MCNPX Monte Carlo (MC) code. To verify the results, experimental data of perc...
full textSurface dose variations in 6 and 10 MV flattened and flattening filter‐free (FFF) photon beams
As the use of linear accelerators operating in flattening filter-free (FFF) modes becomes more widespread, it is important to have an understanding of the surface doses delivered to patients with these beams. Flattening filter removal alters the beam quality and relative contributions of low-energy X-rays and contamination electrons in the beam. Having dosimetric data to describe the surface do...
full textSimulation of a 6 MV Elekta Precise Linac photon beam using GATE/GEANT4.
The GEANT4-based GATE Monte Carlo (MC) platform was initially focused on PET and SPECT simulations. The new release v6.0 (February 2010) proposes new tools dedicated for radiation therapy simulations. In this work, we investigated some part of this extension and proposed a general methodology for Linac simulations. Details of the modeling of a 6 MV photon beam delivered by an Elekta Precise Lin...
full texton the relationship between using discourse markers and the quality of expository and argumentative academic writing of iranian english majors
the aim of the present study was to investigate the frequency and the type of discourse markers used in the argumentative and expository writings of iranian efl learners and the differences between these text features in the two essay genres. the study also aimed at examining the influence of the use of discourse markers on the participants’ writing quality. to this end the discourse markers us...
15 صفحه اولInvestigation of Neutron Contamination of Flattening Filter and Flattening Filter-Free 10-MV Photon Beams in Elekta InfinityTM Accelerator
Introduction: This study aimed to measure the neutron contamination of flattening filter (FF) and flattening filter-free (FFF) 10-MV photon beams delivered by the Elekta InfinityTM accelerator. Material and Methods: The photoneutron spectrum produced by the Linac head was evaluated using a Monte Carlo (MC) simulation. The geometry ...
full textMy Resources
Journal title
volume 17 issue 4
pages 260- 265
publication date 2020-07-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023