Physiological distribution and range of normal SUVmax values of 18F-Choline PET/CT

Authors

  • Antonios Dimosthenis Kalkinis Royal Free Hospital, Pond Street, London, UK
Abstract:

Introduction: 18F-Choline PET-CT is an increasingly used technique in patients with prostate cancer. The main indication is to localise the disease in patients with biochemical recurrence. To accurately interpret 18F-Choline PET, knowledge of normal tracer distribution is paramount. The aim of this study was to describe the normal distribution pattern of 18F-Choline by measuring the maximum standardized uptake values (SUVs) of various organs. Methods:18F-Choline PET was performed in ten consecutive patients. Approximately 370 MBq of tracer was injected intravenously and a low amperage CT scan was performed for attenuation correction of PET images.Maximum SUVs were calculated on the reconstructed images for various organs. These SUVmax values depend on multiple factors and could be variable depending on the reconstruction CT methods, acquisition time and region of interest (ROI) parameters. Results:Physiologic symmetric increased tracer uptake was noted in the salivary glands and parotid glands. Intense physiological uptake was present in the liver, pancreas, duodenum, stomach, kidneys and urinary bladder and moderate to intense uptake in the sublingual glands, lacrimal glands, nasal mucosa, thyroid gland, tonsils, adrenal glands, large bowel, bone marrow and spleen. Low-grade-to-moderate uptake was present in the choroid plexus, pituitary gland, soft palate, pharynx, left myocardium, lungs, mediastinal blood pool, testicles and muscles. Prostate and prostatic beds were excluded from the volumes of interest. Conclusion: This study is the first one to describe a normal range of SUVmax values for 18F-CholinePET in various organs.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

physiological distribution and range of normal suvmax values of 18f-choline pet/ct

introduction: 18f-choline pet-ct is an increasingly used technique in patients with prostate cancer. the main indication is to localise the disease in patients with biochemical recurrence. to accurately interpret 18f-choline pet, knowledge of normal tracer distribution is paramount. the aim of this study was to describe the normal distribution pattern of 18f-choline by measuring the maximum sta...

full text

Physiological distribution and range of normal SUVmax values of F-Choline PET/CT

Introduction: F-Choline PET-CT is an increasingly used technique in patients with prostate cancer. The main indication is to localise the disease in patients with biochemical recurrence. To accurately interpret F-Choline PET, knowledge of normal tracer distribution is paramount. The aim of this study was to describe the normal distribution pattern of F-Choline by measuring the maximum standardi...

full text

study the effects of low level laser diode on no production and healing of diabetic and cortisone acetate and normal wounded sd rats

nitric oxide (no) is a small molecule synthesized by most of mammalian cells with diverse biological activities including vasodilatation, host defense and wound healing. impaired wound healing is a common occurrence among diabetics and patients receiving glucocorticoid therapy. on the other hand the application of laser in biomedical area have been increased. thus, the current studies were desi...

15 صفحه اول

molecular and physiological characterizations of floral scent production in rosa damascena mill.

گل محمدی (r. damascena mill.)مهمترین گونه ای است که در تولید گلاب، عطر و اسانس، در صنعت عطرسازی و دارویی کاربرد دارد. با وجود اهمیت عطر گل محمدی، پژوهش های مولکولی و بیوشیمیایی عطر گل این گونه هنوز در مراحل ابتدایی است. در این پژوهش، ویژگی های مولکولی و فیزیولوژیکی تولید عطر در گل محمدی در آزمایش های مختلف مورد بررسی قرار گرفتند. در آزمایش اول، پژوهشی به منظور بررسی تنوع شیمیایی اسانس میان 44 ت...

coordination of protective schemes in distribution and subtransmission systems including distributed generation

نصب منابع پراکنده در سیستم های توزیع و فوق توزیع علاوه بر مزیت های فراوان، مشکلاتی را هم به همراه دارد. یکی از این مشکلات تأثیر این منابع روی اندازه جریان های اتصال کوتاه است. به طور معمول از حفاظت های مبتنی بر اصل جریان زیاد در سیستم های توزیع و فوق توزیع استفاده می شود. از مهمترین طرح های حفاظتی استفاده شده در فیدرهای توزیع، حفاظت فیوز- ریکلوزر است. همچنین از طرح های حفاظتی جریان زیاد جهتی در...

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 24  issue 1

pages  65- 68

publication date 2016-01-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023