Persistent sub-diaphragmatic activity on the myocardial perfusion scan with 99mTc-Sestamibi

Authors

  • Mehdi Momennezhad Department of Nuclear Medicine, Imam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran
  • Ramin Sadeghi Department of Nuclear Medicine, Imam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran
  • Rasoul Zakavi Department of Nuclear Medicine, Imam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran
Abstract:

We present a female patient with atypical chest pain who was referred to our department for ischemia evaluation. 99mTc-MIBI myocardial perfusion scan with dipyridamole stress was performed. Sub-diaphragmatic activity in the hepatic tissue and then in the bowel loops caused severe overlap on the inferior wall even on consecutive delayed images. Dipyridamole stress was repeated for the patient with 201Tl. The study was interpretable this time without any interfering sub-diaphragmatic activity.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

persistent sub-diaphragmatic activity on the myocardial perfusion scan with 99mtc-sestamibi

we present a female patient with atypical chest pain who was referred to our department for ischemia evaluation. 99mtc-mibi myocardial perfusion scan with dipyridamole stress was performed. sub-diaphragmatic activity in the hepatic tissue and then in the bowel loops caused severe overlap on the inferior wall even on consecutive delayed images. dipyridamole stress was repeated for the patient wi...

full text

Persistent Sub - diaphragmatic Activity on the Myocardial Perfusion Scan with 99 mTc - Sestamibi

We present a female patient with atypical chest pain who was referred to our department for ischemia evaluation. Tc-MIBI myocardial perfusion scan with dipyridamole stress was performed. Sub-diaphragmatic activity in the hepatic tissue and then in the bowel loops caused severe overlap on the inferior wall even on consecutive delayed images. Dipyridamole stress was repeated for the patient with ...

full text

Benefits of combined pharmacologic and submaximal exercise stress on Sub-diaphragmatic activity in myocardial perfusion scintigraphy

Introduction: Myocardial perfusion imaging (MPI) is an important imaging modality in managing patients with cardiovascular disease. MPI has a significant role in diagnosis and management of cardiovascular disease; however it is subjected to different artifacts. Combining pharmacologic stress with submaximal exercise reduces side effects, improves image quality, and enhances the...

full text

Filter selection for 99mTc-Sestamibi myocardial perfusion SPECT imaging [Persian]

Myocardial perfusion SPECT imaging with Tc99m-sestamibi is the most accurate non-invasive means of detecting coronary artery disease and assessing the severity of perfusion abnormalities in the patients with coronary stenosis. Though simple and straight forward the results produced by the technique is very much affected by the details being used. One of the main problems with the test, wh...

full text

Incidental Detection of Thyroid Neoplasm on 99mTc-SestaMIBI Myocardial Perfusion Scan - A Novel Tumour Tracer Revisted

We report a case of a young Indian male who had an incidental abnormal focal uptake of 99mTechnetium-MIBI (Methoxy Isobutyl Isonitrile) in the right lobe of thyroid while undergoing 99mTc-MIBI myocardial perfusion gated SPECT (Single Photon Emission Computed Tomography) imaging as a part of his myocardial ischemia status evaluation. This focal uptake was eventually detected to be a malignant th...

full text

Large abdominal photopenic area on 99mTc-sestamibi myocardial perfusion imaging.

(99m)Tc-sestamibi myocardial perfusion imaging is frequently performed in conjunction with exercise or pharmacologic stress testing for evaluation of coronary heart disease. Interpretation of these studies includes systematic review of unprocessed rotating projectional images for evaluation of cardiac size as well as the presence of motion or attenuation artifacts. Occasionally, incidental nonc...

full text

My Resources

Save resource for easier access later