Performance Evaluation of Tile Wastewater Treatment with Different Coagulants
Authors
Abstract:
Introduction: The objective of this study was to investigate wastewater quality and the efficiency of removal of wastewater contaminants produced by a tile factory by using ferric chloride, ferrous sulfate, ferric sulfate, aluminum sulfate (alum) and poly-aluminum chloride (PAC) coagulants. Materials and Methods: This is an applied study. A composite sample was taken of the wastewater production line of the factory. Wastewater characteristics including pH, EC, temperature, turbidity, TSS, TDS, TS and COD were measured in accordance with the standard methods. In the next step, the jar-test experiment was used to investigate the effect of changing doses of coagulants (0.15, 0.2, 0.25, 0.3, 0.35 g/L) and pH values (7, 9, 11) on the removal of contaminants. The effective dose and optimal pH were thus selected and the best coagulant was later determined. Results: The optimum pH of 11 was obtained for removal of contaminants by ferric chloride, ferric, ferrous sulfate and 7 for alum and PAC. The optimum concentration of the five coagulants was obtained at 0.3, 0.3, 0.3, 0.25, 0.25 g/L respectively. PAC, with the turbidity removal EC, TSS, TS and COD removal of 99.92%,17.74%, 99.93%, 89.8%, 75% respectively, had best performance at lower doses and alum, ferrous sulfate, chloride, ferric and ferric sulfate were placed in the next rankings. Conclusion: Among the five studied coagulants, PAC is the most effective coagulant, and then alum, ferrous sulfate, ferric chloride and ferric sulfate are placed. Given that PAC is more expensive than other materials, care should be taken to select the most appropriate coagulant.
similar resources
Performance Evaluation of Tile Wastewater Treatment with Different Coagulants
Introduction: The objective of this study was, wastewater quality investigation and removal efficiency of contaminants from the wastewater tile factory by using coagulants includes ferric chloride, ferric sulfate and ferrous, aluminum sulfate and poly aluminum chloride in order to reuse it in the processing line. Methods: This is an applied study. With regard to shiftwork schedules of the facto...
full textperformance evaluation of tile wastewater treatment with different coagulants
introduction: the objective of this study was, wastewater quality investigation and removal efficiency of contaminants from the wastewater tile factory by using coagulants includes ferric chloride, ferric sulfate and ferrous, aluminum sulfate and poly aluminum chloride in order to reuse it in the processing line. methods: this is an applied study. with regard to shiftwork schedules of the fact...
full textevaluation of industrial dyeing wastewater treatment with coagulants
textile industry is the major source of water consumption and wastewater pollution.there are various treatment techniques to remove textile wastewater pollution. coagulationflocculation is a widely used process to remove pollution due to suspended particles. in this research, different coagulants like alum, lime, fecl3, feso4 and mgcl2 were applied to select the suitable ones with optimum remov...
full textUse of natural coagulants for industrial wastewater treatment
Industrial effluents are a menace to the environment and the fact that their characteristics vary from industry-to-industry only adds to the complex challenge they offer to the engineers and scientists. Resource-efficient and environment-friendly solutions to this hazard are a call of the hour. Coagulation, by synthetic chemicals, has been used as a cost-effective and efficient method for manag...
full textEvaluation of sequencing batch reactor performance for petrochemical wastewater treatment
Sequencing batch reactor (SBR) technology has found many applications in industrial wastewater treatment in recent years. The aim of this study was to determine the optimal time for a cycle of the sequencing batch reactor (SBR) and evaluate the performance of a SBR for petrochemical wastewater treatment in that cycle time. The reactor was operated with a suspended biomass configuration under ae...
full textOptimizing functions of coagulants in treatment of wastewater from metalworking fluids: Prediction by RSM method
Background: Coagulation is a treatment procedure for metalworking fluids (MWFs). This study aimed to optimize coagulation using four coagulants and compare the results. Methods: In this research, the outputs of a coagulation procedure in chemical oxygen demand (COD) removal, turbidity, and the release of oil were investigated using four coagulants, ferric chloride (FeCl3), ferric sulfate (Fe2(...
full textMy Resources
Journal title
volume 1 issue 1
pages 18- 27
publication date 2016-06
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023