Patient dose resulting from CT examinations in Yazd, Iran
Authors
Abstract:
Background: With the introduction of computed tomography in diagnostic radiology a new and fundamentally different imaging modality has become available. Meanwhile, it is clear that the absorbed doses by the patients during CT were relatively high in comparison with those of other diagnostic radiology techniques. The aim of this survey was to determine the average absorbed dose in Yazd province by CT examinations, and to survey the potential risks per year by these examinations. Materials and Methods: This study was conducted in CT centers of Yazd during 2005-2006. The examination frequencies from 3 CT scanners were collected from all types of examinations. Effective dose were determined by CT Dose program (ImPACT CT patient dosimetry calculator). To use of this software, CTDIair, mAs and the thickness and number of slices in each type of CT examinations should have been measured. CTDIair was measured by pencil diode detector. Results: It was estimated that the annual collective dose and caput dose were about 32.48 Person-Sv and 0.038 mSv, respectively for the Yazd population, which is lower than that reported for other countries. The numbers of examinations per 1000 people of Yazd was 18 which were equal to many other countries such as UK and New Zealand. The mean effective dose of each CT examinations was also lower than that of other countries. Conclusion: Using the ICRP risk factors, radiation dose from CT could be induced to about 1 fatal cancer per year in Yazd. Therefore choosing CT imaging must be completely justified.
similar resources
patient dose resulting from ct examinations in yazd, iran
background: with the introduction of computed tomography in diagnostic radiology a new and fundamentally different imaging modality has become available. meanwhile, it is clear that the absorbed doses by the patients during ct were relatively high in comparison with those of other diagnostic radiology techniques. the aim of this survey was to determine the average absorbed dose in yazd province...
full textAssessment of Patient Dose from CT Examinations in Khorasan, Iran
Introduction Computed Tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. Ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. Yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. Materials and Methods Two refe...
full textassessment of patient dose from ct examinations in khorasan, iran
introduction computed tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. materials and methods two refe...
full textPatient dose in routine X-ray examinations in Yazd state
Background: Medical x-rays are the largest man-made source of public exposure to ionizing radiation. It is important to avoid conditions where the amount of radiation used is more than that needed for the procedure. Materials and Methods: The Entrance Skin Exposure (ESE) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. The ESEs we...
full textPatient dose values during interventional cardiology examinations in Yazd hospital, Iran
Background: The number of interventional cardiology (IC) procedures has increased rapidly. coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. However, it is also known that these procedures are associated with high radiation doses due to long f...
full textpatient dose in routine x-ray examinations in yazd state
background: medical x-rays are the largest man-made source of public exposure to ionizing radiation. it is important to avoid conditions where the amount of radiation used is more than that needed for the procedure. materials and methods: the entrance skin exposure (ese) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. the eses we...
full textMy Resources
Journal title
volume 4 issue None
pages 121- 127
publication date 2006-12
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023