Passive Energy Air-to-Water Heat Pipe Based Heat Exchanger and its Potential of Air Pre-cooling in Air Conditioning Systems for Iran Climate

author

Abstract:

Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To this end, effectiveness-NTU approach was employed to determine the thermal performance of the heat exchanger. Water-to-air HPHEX with different numbers of rows namely two, four, and six was studied to determine the heat transfer characteristics of the heat exchanger. The thermal performance of the water-to-air HPHEX was investigated under different operating conditions in terms of evaporator inlet air and condenser inlet water coil face velocities and temperatures. After determining the thermal performance of the water-to-air HPHEX, the air pre-cooling capability of the water-to-air HPHEX was explored hour-by-hour for the required months of the year by using TRNSYS software. Based on the simulations results, the water-to-air HPHEX shows an acceptable thermal performance under the operating conditions. In addition, studies showed that the water-to-air HPHEX has a significant capability for air pre-cooling, which makes it applicable to be implemented in the air-conditioning systems operating in south of Iran.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Fully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology

The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...

full text

Heat transfer enhancement due to air bubble injection into a horizontal double pipe heat exchanger

If an air flow is injected into a liquid fluid, many ambulant air bubbles are formed inside the fluid. Air bubbles move inside the liquid fluid because of the buoyancy force, and the mobility of these air bubbles makes sizable commixture and turbulence inside the fluid. This mechanism was employed to enhance the heat transfer rate of a horizontal double pipe heat exchanger in this paper. Howeve...

full text

Evaluation of Peak Shifting and Energy Saving Potential of Ice Storage Based Air Conditioning Systems in Iran

Thermal energy storage (TES) system has been introduced as a practical facility for shifting load from peak hours to off-peak hours. Because of different energy consumption during day and night, peak and off peak period is created on load curve. Ice storage technology which is a kind of TES system, is implemented in different points of the world with the purpose of solving load shifting problem...

full text

Diagnosis of Heat Exchanger Scales in Cooling Water Systems

An experimental database is compiled in order to fingerprint the scales formed over the hot surfaces of heat exchangers, in cooling water systems or other systems with similar chemistry. To collect these data, a dynamic simulating pilot plant was designed with considerable application flexibility among which simultaneous flow of water with different velocity and heat fluxes to three simulat...

full text

heat transfer enhancement due to air bubble injection into a horizontal double pipe heat exchanger

if an air flow is injected into a liquid fluid, many ambulant air bubbles are formed inside the fluid. air bubbles move inside the liquid fluid because of the buoyancy force, and the mobility of these air bubbles makes sizable commixture and turbulence inside the fluid. this mechanism was employed to enhance the heat transfer rate of a horizontal double pipe heat exchanger in this paper. howeve...

full text

Evaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners

There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 3  issue 3

pages  44- 52

publication date 2016-08-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023