Pancake kidney: An unusual type of renal fusion anomaly found in 99mTc-DMSA renal scintigraphy

Authors

  • Behroz Davachi Radiology Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
  • Kamran Aryana Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
  • Narjess Ayati Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
  • Sara Shakeri Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
  • Toktam Massoudi Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
Abstract:

A 2.5-year-old boy with a history of the previous incidental finding of an ectopic kidney in ultrasonography was referred to our nuclear medicine center for 99mTc-DMSA renal scintigraphy. The scan showed an unusual type of ectopic fused kidneys on the right side of the lower abdomen. In this anomaly, kidneys were fused completely across the medial portion of both upper and lower poles, as well as hilum with no septum. Each kidney, however, demonstrated separate consists of own collecting system. 99mTc-DMSA renal scintigraphy is a valuable imaging detection of different shape anomalies such as pancake kidney. We report this extremely rare case of ectopic fused types of renal anomaly including pancake kidney.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Pancake Kidney With Obstructed Moiety: A Rare Renal Fusion Anomaly

Renal fusion abnormalities are rare. Even more rare is pancake kidney. We present a case of a 28-year-old male with symptomatic obstruction of a non-functioning moiety of a pancake kidney. He underwent ureterectomy with a finding of only atretic renal parenchyma at exploration. He recovered well and had resolution of his pain at 3-month follow-up.

full text

Assessment of the maximum uptake time of 99mTc-DMSA in renal scintigraphy in rat

Introduction:The optimal imaging time of a radionuclide scintigraphy is the time at which the organ of interest has the maximum uptake of the injected radionuclide. This study was performed to investigate the maximum uptake time of 99mTc-DMSA in rat renal scan. Methods: Renal scintigraphy was performed with 3 mCi of 99mTc-DMSA. Planar ima...

full text

The comparison between ultrasonography and 99mTc-DMSA renal scan in estimation of kidney size

Introduction: Renal length measurement is an important diagnostic clue in several urinary tract abnormalities. Although ultra sonography is the most frequent used modality for renal size estimation, renal diameter assessment by 99mTc-DMSA scintigraphy is of great value. By now, pointing to the renal size in the 99mTc-DMSA scintigraphy report has not been recommended by gui...

full text

Unilateral renal agenesis revealed by hydronephrosis of contralateral kidney and explored by 99mTc-DMSA and 99mTc-DTPA scintigraphy

Renal scintigraphy is a physio-functional exploration permitting the exploration and assertion of unilateral renal agenesis. We report the case of a patient followed for a right hydronephrosis having revealed an agenesis of the contralateral kidney confirmed by 99mTc-DMSA scintigraphy. Also 99mTc-DTPA scintigraphy allowed the evaluation of the permeability of the urinary tract of the single rig...

full text

Assessment of the maximum uptake time of 99mTc-DMSA in renal scintigraphy in rat

Introduction: The optimal imaging time of a radionuclide scintigraphy is the time at which the organ of interest has the maximum uptake of the injected radionuclide. This study was performed to investigate the maximum uptake time of 99mTc-DMSA in rat renal scan. Methods: Renal scintigraphy was performed with 3 mCi of 99mTc-DMSA. Planar images were acquired every 20 minutes for 8 hours post-inje...

full text

Comparison of IVP-simulator and 99mTc-DMSA renal scaning for renal localization and shielding in candidates for radiation therapy [Persian]

To minimize renal radiation in abdomical radiotherapy, shielding of the kidneys is essential. IVP-simulator is used as an standard method. In this study, we used 99mTc-DMSA to localize and shield the Kidneys and we compared this method with IVP-simulator. The size of the kidneys was proven to be larger as compared with IVP method. The mean of the overlap percentage was 81.88 in right and ...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 27  issue 1

pages  60- 62

publication date 2019-01-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023