Paediatric Dose AssessmentToward Establishment of National Diagnostic Reference Levels for Digital Radiography Examinations in Iran
Authors
Abstract:
Introduction: Paediatric patients deserve special attention because of the higher radiation risks compared with adults. The main purpose of this study is to determine patient dose and diagnostic reference level for Paediatric through Entrance Surface Dose (ESD) calculations in common X-ray examination and to establish Paediatric national DRLs in digital radiography in Iran. Materials and Methods: The study was performed on 5260 patients in 53 X-ray room. They are classified into four age groups, 0>1 year, 1>5 years, 5>10 years and 10>15 years old. Skull (PA), Skull (Lat), Chest (PA), Chest (Lat), Pelvis(AP), Abdomen (AP) digital X-ray examination is done for them. The dosimetry protocol in this study was indirect method to measure Entrance Surface Air Kerma (ESAK). The X-ray tube output for each equipment is measured using RTI solid state detector (Model Barracuda). Finally, the third quarter determined diagnostic reference level. Results: Based on the results of this study, national diagnostic reference levels were established: for example, for age group 0 to 1-year-old: 0.51 mGy for Skull(AP/PA), 0.46 mGy for Skull(Lat), 0.11 mGy for Cervical spine(AP), 0.11 mGy for Cervical spine(Lat), 0.06mGy for Chest(PA), 0.08 mGy Chest(Lat), 0.15 mGy for Thoracic spine(AP), 0.26 mGy for Thoracic spine (Lat), 0.48 mGy for Lumbar spine (AP), 0.74 mGy for Lumbar spine(Lat), 0.47 mGy for Pelvis (AP) and 0.47 mGy for Abdomen (AP). Conclusion: This article has determined wide variations in radiation dose of x-ray examinations among hospitals in Iran. Application of a diagnostic reference levels (DRL) could be a optimization procedure for reducing patients dose. The survey reveals significant variations in the radiological practices.
similar resources
The need for national diagnostic reference levels: Entrance surface dose measurement in intraoral radiography
Background: Intraoral radiographies are the most frequent X-ray examinations in humans. According to International Commission on Radiation Protection (ICRP) recommendations, the selection of a diagnostic reference level (DRL) should be specific to a country or region. Critica l organs such as thyroid gland are exposed to X-rays in intraoral radiography and these exposures should be kept as low ...
full textDiagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey
Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...
full textDose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran
Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...
full textLocal Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran
Introduction: Diagnostic reference level (DRL) is a useful tool for the promotion of optimization. The national DRLs (NDRLs) are useful, brief, and robust guidelines for optimizing radiation protection in a country. The aim of this study was to extract the local DRLs (LDRLs) for some common radiologic examination in Sabzevar county. Materials and Methods: There are eight radiology departments ...
full textLocal reference dose evaluation in conventional radiography examinations in Iran
The goal of this study was to establish local diagnostic reference levels (LDRLs) for conventional radiography examinations in Sistan-Baluchestan province of Iran, using dose area product (DAP) measurements followed by a comparison with international dose levels. DAP factor evaluation was carried out at eight radiography rooms in six public and one private health-care centers. The study employe...
full textthe need for national diagnostic reference levels: entrance surface dose measurement in intraoral radiography
background: intraoral radiographies are the most frequent x-ray examinations in humans. according to international commission on radiation protection (icrp) recommendations, the selection of a diagnostic reference level (drl) should be specific to a country or region. critica l organs such as thyroid gland are exposed to x-rays in intraoral radiography and these exposures should be kept as low ...
full textMy Resources
Journal title
volume 15 issue Special Issue-12th. Iranian Congress of Medical Physics
pages 94- 94
publication date 2018-12-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023