Organ and effective dose arising from conventional diagnostic X-ray examinations by Monte Carlo simulation (MCNP-4C Code)

Authors

Abstract:

 ABSTRACTBackground: Monte Carlo simulation has been used by many researchers to calculate organ and effective dose of patients arising from conventional X-ray examinations. In this study the radiation transport code, MCNP-4C, has been used to perform Monte Carlo simulations to estimate radiation dose delivered to different organs in conventional X-ray examinations.Material and Methods: In this work we have made use of ORNL mathematical phantoms with few modifications which have been made. The source has been defined as a point source, emitting photons into a solid angle. The X-ray beam was shaped by a collimator to produce a rectangular field at the midline of the phantom. Results: To validate the simulation executed in this study normalized organs doses to unit ESD for hermaphrodite phantom were computed. Our results were compared with corresponding values presented by NRPB. In general organs doses obtained by application of MCNP-4C (present study) and corresponding values presented in NRPB were in good agreement. For further evaluation of our phantom, the values acquired for organ and effective doses by MCNP-4C and ODS-60 were compared. Conclusion: The technique we have developed is capable of estimating organ and effective doses with a better accuracy than dose values obtained by employment of NRPB and ODS-60 technique. 

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Unfolding X-ray spectrum in the diagnostic range using the Monte Carlo Code MCNP5

Introduction: Unfolding X-ray spectrum is a powerful tool for quality control of X-ray tubes. Generally, the acquisition of the X-ray spectrum in diagnostic radiology departments is complicated and difficult due to high photon flux. Measurement of x ray spectra using radiation detectors could not be performed accurately, because of the pulse pile up. Therefore, indirect methods...

full text

Evaluation of Organ and Effective Doses to Patients Arising From Some Common X-Ray Examinations by PCXMC Program in Sabzevar, Iran

Introduction The purpose of this study was to estimate organ and effective doses in patients undergoing some common X-ray examinations in Sabzevar, Iran. The effective dose is one of the best parameters for describing the amount of radiation dose received by a patient undergoing any diagnostic X-ray examination. The public dose from X-ray examinations depends on various factors, and its contrib...

full text

Evaluation of Organ Specific peripheral dose for Gamma knife 4C based on Monte Carlo

Introduction: Stereotactic Gamma Knife radiosurgery has been widely used for treating brain tumors. The scattered radiation outside of treatment field (peripheral dose) can induce the secondary cancer to specific organ. This paper investigated the absorbed dose to eyes, thyroid, heart, lung, breast and colon using a Monte Carlo technique for Mird phantom. We also study the ef...

full text

Evaluation of X-ray absorbed dose in thyroid during CXR imaging of the chest by Monte Carlo simulation (DOSXYZnrc)

Abstract:   Introduction: Chest radiography is one of the most common X-ray imaging procedures performed worldwide. During this process, in addition to the chest, other tissues, including the thyroid, are also exposed to radiation. Due to the fact that one of the most important risk factors for thyroid cancer is ionizing radiation, measuring the absorption of X- rays in the thyroid is of spec...

full text

Monte Carlo Method for Radiological X-ray Examinations

The organ doses and the effective dose of patients exposed at an X-ray beam, having photon energies between 10–150 keV, are analyzed by using a new method named IradMed. Three major radiological procedures, mammography, radiography and Computer Tomography are considered. The Rayleigh scattering, the Compton scattering and the photoelectric effect were taken into account for patient dose calcula...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 3  issue None

pages  21- 30

publication date 2005-06

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023