Optimization of tangential fields arrangement in the breast cancer 3D conformal radiation therapy

Authors

  • Mostafa Robatjazi Medical Physics and Radiological Sciences Department, Sabzevar University of Medical Sciences, Sabzevar, Iran Vasei Radiotherapy & Oncology Center, Sabzevar University of Medical Sciences, Sabzevar, Iran
  • Pejman Porohan Vasei Radiotherapy & Oncology Center, Sabzevar University of Medical Sciences, Sabzevar, Iran
Abstract:

Introduction: The incidence of breast cancer increases with the rate of 1-2% at the world. Radiation therapy is one of the available choices for breast cancer treatment. The single isocentre half-beam block technique is considered as a standard technique to avoid hot and cold spots within the PTV. The major advantage of half beam technique is that the both contralateral breast and lung are completely spared. Also, using this technique, we don’t have any field matching problem. But, Lateral and medial movement of isocenter in conjunction of supraclavicular and tangential beams affect the divergence of tangential fields. Therefore, opposite tangential field can be parallel either in posterior border or beam central axis. The aim of this study is to compare the dosimetric parameters of three plans for tangential beams arrangement and select the optimal one.     Materials and Methods: In this study, we selected 6 patients with breast cancer that underwent breast conserving surgery and considered for radiotherapy. CT simulation of patients were done based on standard protocols and imported to Isogray treatment planning system. Contouring of target volume and organs at risk (OARs) was done by radiotherapist. The tangential fields were considered in three different geometries of parallel in the posterior border with divergence in back jaws, parallel in central axis with divergence in back jaws and Parallel in posterior border without divergence of back jaws (half beam). Dosimetric parameters of each plan for OARs and target volumes extracted from DVHs data and compared statistically using ANOVA one-way repeated measurement test.   Results: There was no statistical difference between dosimetric parameters (D95, V95, Dmax, and Dmean) of the target volume in three mentioned plans (P-value = 0.93). Although, there was no statistical difference between mean dose of the ipsilateral lung, the difference of V10 and V20 parameters for this organ is significant (P=0.01). Furthermore, there was no statistical difference in dosimetric parameters of OARs such as contralateral breast, lung, heart, and spinal cord.   Conclusion: This study showed that back jaw divergence and arrangement of parallel opposite field can affect the ipsilateral lung dose. The V20 and V10 of ipsilateral lung are two dose constraints parameters in quantitative treatment planning evaluation of breast treatment. Quantitative variations of these parameters with changing the tangential field’s arrangement was significant which depends on the isocenter position and back jaw divergence. The values of these parameters were the highest when tangential fields were arranged as parallel in posterior border with divergence in the back jaw.  

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

optimizing of the tangential technique and supraclavicular fields in 3 dimensional conformal radiation therapy for breast cancer

radiotherapy plays an essential role in the management of breast cancer. three-dimensional conformal radiation therapy (3d-crt) is applied based on 3d image information of anatomy of patients. in three-dimensional conformal radiation therapy (3d-crt) for breast cancer one of the common techniques is tangential technique. in this project, various parameters of tangential and supraclavicular fiel...

full text

Optimization of 3D Planning Dosimetry in a Breast Phantom for the Match Region of Supraclavicular and Tangential Fields

Introduction: The complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (PTV) result in perturbations in dose distribution. This problem can result in overdosage or underdosage in the match region of the three treatment fields. The purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and t...

full text

Optimizing of the Tangential Technique and Supraclavicular Fields in 3 Dimensional Conformal Radiation Therapy for Breast Cancer

Radiotherapy plays an essential role in the management of breast cancer. Three-dimensional conformal radiation therapy (3D-CRT) is applied based on 3D image information of anatomy of patients. In 3D-CRT for breast cancer one of the common techniques is tangential technique. In this project, various parameters of tangential and supraclavicular fields are optimized. This project has been done on ...

full text

3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk

Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...

full text

Intensity modulated radiation therapy (IMRT) technique for left breast cancer by different numbers of beam fields

Background: Intensity Modulated Radiotherapy (IMRT) can improve radiotherapy (RT) results by improving healthy tissue sparing. Additionally, IMRT provides more consistent dose deliveries and suppresses secondary tumor formation. RT is a principal treatment in breast cancer (BC). Aim: To evaluate the outcome of the Radiotherapy Plans (RTP) that use IMRT technique to left breast and other organs,...

full text

the study of aaag repeat polymorphism in promoter of errg gene and its association with the risk of breast cancer in isfahan region

چکیده: سرطان پستان دومین عامل مرگ مرتبط با سرطان در خانم ها است. از آنجا که سرطان پستان یک تومور وابسته به هورمون است، می تواند توسط وضعیت هورمون های استروئیدی شامل استروژن و پروژسترون تنظیم شود. استروژن نقش مهمی در توسعه و پیشرفت سرطان پستان ایفا می کند و تاثیر خود را روی بیان ژن های هدف از طریق گیرنده های استروژن اعمال می کند. اما گروه دیگری از گیرنده های هسته ای به نام گیرنده های مرتبط به ا...

15 صفحه اول

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  265- 265

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023