Optimization of Dose and Image Quality in Full-fiand Computed Radiography Systems for Common Digital Radiographic Examinations

Authors

Abstract:

IntroductionA fine balance of image quality and radiation dose can be achieved by optimization to minimize stochastic and deterministic effects. This study aimed in ensuring that images of acceptable quality for common radiographic examinations in digital imaging were produced without causing harmful effects. Materials and MethodsThe study was conducted in three phases. The pre-optimization involved ninety physically abled patients aged between 20 to 60 years and weighed between 60 and 80 kilograms for four common digital radiographic examinations. Kerma X_plus, DAP meter was utilized to measure the entrance surface dose (ESD) while effective dose (ED) was estimated using CALDose_X 5.0 Monte Carlo software. The second phase, an experimental study utilized an anthropomorphic phantom (PBU-50) and Leeds test object TOR CDR for relative comparison of image quality. For the optimization phase, the imaging parameters with acceptable image quality and lowest ESD from the experimental study was related to patient’s body thickness. Image quality were evaluated by two radiologists using the modified evaluation criteria score lists. ResultsSignificant differences were found for image quality for all examinations. However significant difference for ESD were found for PA chest and AP abdomen only. The ESD for three of the examinations were lower than all published data. Additionally, the ESD and ED obtained for all examinations were lower than that recommended by radiation regulatory bodies. ConclusionOptimization of image quality and dose was achieved by utilizing an appropriate tube potential, calibrated automatic exposure control and additional filtration of 0.2mm copper.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

A Phantom Study for the Optimization of Image Quality and Radiation Dose for Common Radiographic Examinations in Digital Radiography

Introduction: Phantom studies facilitate the implementation of radiation dose surveillance as a function of radiographic technical parameters for minimizing patient radiation dose. The evidence of such investigations can then be used to evaluate technical parameters used in the radiographic procedures to reduce radiation dose without compromising the image quality. Material and Methods: This ex...

full text

Dose Evaluation for Common Digital Radiographic Examinations in Selected Hospitals in Pahang Malaysia

Introduction: In digital radiography, radiographers tend to increase exposure factors to acquire an acceptable image quality thereby increasing radiation dose to patients.  Regarding this, the present study aimed to re-evaluate the exposure parameters and to ascertain the entrance surface dose (ESD) and effective dose (ED) of posterior-anterior (PA) chest, abdomen, and anterior-posterior (AP) l...

full text

The Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality

Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality.  Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...

full text

Optimization of chest radiographic imaging parameters: a comparison of image quality and entrance skin dose for digital chest radiography systems.

We studied the performance of three computed radiography and three direct radiography systems with regard to the image noise and entrance skin dose based on a chest phantom. Images were obtained with kVp of 100, 110, and 120 and mA settings of 1, 2, 4, 8, and 10. Significant differences of image noise were found in these digital chest radiography systems (P<.0001). Standard deviation was signif...

full text

Effects of Kilovoltage on Image Quality and Entrance Surface Dose in Lumbar Spine Digital Radiography

Introduction: Digital radiography possesses a wide dynamic range and has a major advantage in producing an acceptable image of diagnostic value even though overexposure occurs. Lumbar spine (LS) radiography is the most common examinations that gives high radiation dose to patients and accounts for the highest collective population dose of any conventional radiographic ...

full text

Paediatric Dose AssessmentToward Establishment of National Diagnostic Reference Levels for Digital Radiography Examinations in Iran

Introduction: Paediatric patients deserve special attention because of the higher radiation risks compared with adults. The main purpose of this study is to determine patient dose and diagnostic reference level for Paediatric through Entrance Surface Dose (ESD) calculations in common X-ray examination and to establish Paediatric national DRLs in digital radiography in Iran. <...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue 1

pages  28- 38

publication date 2018-01-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023