Optimization of a SPECT system for imaging of 90Y in liver using Monte Carlo method

Authors

  • Asghar Hadadi Department of nuclear engineering, science and research branch, Islamic Azad University, Tehran, Iran
  • Farshid babapoor Mofrad Department of nuclear engineering, science and research branch, Islamic Azad University, Tehran, Iran
  • Jalil Pirayesh Islamian Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
  • Mohammad Khoshakhlagh Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
  • Sedigheh Jafari Department of nuclear engineering, science and research branch, Islamic Azad University, Tehran, Iran
Abstract:

Introduction: Acquiring a high quality image has assigned an important concern for obtaining accurate diagnosis in nuclear medicine. Detector and collimator are critical component of Single Photon Emission Computed Tomography (SPECT) imaging system for giving accurate information from exact pattern of radionuclide distribution in the target organ. The images are strongly affected by the attenuation, scattering, and response of the detector and collimator.   Method and material: The Planar and SPECT scans of a Y90 point source and also an extended Cardiac- Torso(XCAT) computerized phantom with the experiment and simulated systems were prepared. The SIMIND Monte Carlo program was used for simulating Siemen’s dual head variable angle SPECT imaging system with 4 detectors and 10 collimators. After verification and validation of the simulated system, the similar scans of the phantoms were compared from the point of view of image quality for 4 scintillator crystals including: NaI(Tl), BGO, LuAG: Ce, LaBr3 and also 10 collimators: Pb, Pb-Sb, Pb-Sb3, Pb-bi-Sn19, Pb-bi Sn375, Pb-bi-Sn50, Pb-bi-Sn-cd10, Pb-bi-Sn-cd125, Pt and Pt-Co. The parameters of energy and spatial resolution, and sensitivity of the systems were compared. Images were analyzed qualitatively by two nuclear medicine specialists. RESULTS: FWHM of the mentioned crystals and collimators obtained where: NaI (Pb, 0.3853) and BGO (Pb-Sb, 0.406), (Pb-Bi-Sn375, 0.405), (Pb-Bi-Sn-cd125, 0.375), and LuAG: Ce crystal (Pb-Sb, 0.425), (Pb- Bi-Sn19, 0.407), (Pb-Bi-Sn375, 0.417) and also LaBr3 (Pb-Bi-Sn375, 0.407), (Pb-Bi-Sn50, 0.430), (Pt-Co, 0.355). Medical diagnosis of the SPECT images of the phantom showed that the system with NaI(Tl)and LaBr3 by Pb-Sn3 collimator potentially provides a better detectability for hot lesions in the liver of XCAT phantom. CONCLUSIONS: The results showed that crystal NaI(Tl)and LaBr3 by Pb-Sn3 collimator has a high sensitivity and resolution, and also provides a better lesion detectability from the point of view of image quality on XCAT phantom.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Absorbed dose of Fetus in SPECT-CT Imaging of Mother's Abdomen Regions using Monte Carlo method

SPECT-CT is an imaging method for diagnosing diseases and studying physiology of the body. In this type of imaging, due to the use of radiopharmaceutical for imaging (SPECT) and X-rays (CT), a relatively high dose of radiation is introduced into the patient. If the patient is pregnant, considering that the developing fetus is sensitive to any radiation in the uterus throughout the entire period...

full text

Bremsstrahlung imaging from the liver using the Monte Carlo simulation

Introduction: Most beta and gamma radiation radioisotopes used for treatment are not suitable for imaging. The bremsstrahlung images on a conventional gamma camera helped to localize the radionuclide within and outside of the lesion. Secondary scattering of gamma rays of higher energy and bremsstrahlung causes contamination in the energy window and reducing the contrast and resolution of the im...

full text

Planar and SPECT Monte Carlo acceleration using a variance reduction technique in I131 imaging

Background: Various variance reduction techniques such as forced detection (FD) have been implemented in Monte Carlo (MC) simulation of nuclear medicine in an effort to decrease the simulation time while keeping accuracy. However most of these techniques still result in very long MC simulation times for being implemented into routine use. Materials and Methods: Convolution-based force...

full text

Attenuation Correction in SPECT during Image Reconstruction using an Inverse Monte Carlo Method: A Simulation Study

Introduction: The main goal of SPECT imaging is to determine activity distribution inside the organs of the body. However, due to photon attenuation, it is almost impossible to do a quantitative study. In this paper, we suggest a mathematical relationship between activity distribution and its corresponding projections using a transfer matrix. Monte Carlo simulation was used to find a precise tr...

full text

A Monte Carlo study of SPECT in boron neutron capture therapy for a heterogeneous human phantom

Background: Boron neutron capture therapy (BNCT) is a binary radiotherapy combining biochemical targeting with neutron irradiation. However, monitoring the boron distribution is a fundamental problem in BNCT. Prompt gamma rays emitted by boron capture reaction can be used to address the issue. Materials and Methods: The general-purpose Monte Carlo toolkits Geant4 and MCNP were used for the simu...

full text

Monte Carlo-based optimization of a gamma probe system for sentinel lymph node mapping

Introduction: Sentinel lymph node biopsy (SLNB) is a standard surgical technique to identify sentinel lymph node (SLN) for the staging of early breast cancer. Nowadays, two methods are used for the identification of SLN: blue dye method aiding visually and radioactive dye using gamma detector. A wide range of gamma probe systems with different design and performance are used in...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  262- 262

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.