Optimization of 3D Planning Dosimetry in a Breast Phantom for the Match Region of Supraclavicular and Tangential Fields
Authors
Abstract:
Introduction: The complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (PTV) result in perturbations in dose distribution. This problem can result in overdosage or underdosage in the match region of the three treatment fields. The purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and tangential fields, utilizing Gafchromic EBT film for dosimetry. Material and Methods: In this study, a slab phantom was designed with lung- and heart-equivalent inhomogetenities. Our measurements were carried out using Gafchromic EBT film. Irradiations were performed using the 6 MV photon beam of a Varian 2100 Clinac linear accelerator. Three-dimensional treatment planning and dose calculations were carried out using the RT Dose Plan software. The conventional method with source-to-skin distance match and a 3D method with source-to-axis distance match under different combinations of parameters such as gantry, collimator and couch rotations as well as asymmetric fields were utilized. Results: The results demonstrated differences between the 3D and conventional techniques. The best results in the match region were observed using the 3D method with asymmetric technique (maximum area of overlap = 0.43 cm2, depth of overlap = 3.55 cm, and average width of overlap = 0.75 cm). Discussion and Conclusion: This study shows that the EBT film is a suitable tool for two-dimensional distribution dosimetry and relative dose measurements. The study shows difficulties in achieving a homogenous dose distribution in the match region of supraclavicular and tangential fields and also demonstrates the effects of setup parameters on matching of treatment fields.
similar resources
optimization of 3d planning dosimetry in a breast phantom for the match region of supraclavicular and tangential fields
introduction: the complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (ptv) result in perturbations in dose distribution. this problem can result in overdosage or underdosage in the match region of the three treatment fields. the purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and t...
full textOptimization of three dimensional planning dosimetric in breast phantom for match region of supraclavicular and tangential fields.
AIM Complex geometry of breast tissue causes perturbation in dose distribution. This problem can beget overdose or under-dose points in match region of three fields. The aim of this study is to create dose homogeneity distribution in match region between tangential and supraclavicular fields (SCF) with Gafchromic external beam therapy (EBT) film. MATERIALS AND METHODS In this study, an anatom...
full textOptimization of tangential fields arrangement in the breast cancer 3D conformal radiation therapy
Introduction: The incidence of breast cancer increases with the rate of 1-2% at the world. Radiation therapy is one of the available choices for breast cancer treatment. The single isocentre half-beam block technique is considered as a standard technique to avoid hot and cold spots within the PTV. The major advantage of half beam technique is that the both contralateral breast...
full textthe study of aaag repeat polymorphism in promoter of errg gene and its association with the risk of breast cancer in isfahan region
چکیده: سرطان پستان دومین عامل مرگ مرتبط با سرطان در خانم ها است. از آنجا که سرطان پستان یک تومور وابسته به هورمون است، می تواند توسط وضعیت هورمون های استروئیدی شامل استروژن و پروژسترون تنظیم شود. استروژن نقش مهمی در توسعه و پیشرفت سرطان پستان ایفا می کند و تاثیر خود را روی بیان ژن های هدف از طریق گیرنده های استروژن اعمال می کند. اما گروه دیگری از گیرنده های هسته ای به نام گیرنده های مرتبط به ا...
15 صفحه اولComparing the results of 3D treatment planning and practical dosimetry in craniospinal radiotherapy using Rando phantom
Background: Craniospinal radiotherapy faces technical challenges which are due to the sensitivity of the location in which the gross tumor is, and to organs at risk around planning target volume. Using modern treatment planning systems causes a reduction in the complexities of the treatment techniques. The most effective method to assess the dosimetric accuracy and the validity of the ...
full textDose-volume Analysis of Heart and Lung during 3D planning of Tangential Breast Cancer Irradiation
Background: Breast cancer is becoming more frequently diagnosed at early stages with improved long term outcomes. Radiation-related heart disease and lung cancer can occur following radiotherapy for breast cancer. The aim of this study was to evaluate some dosimetric parameters of heart and lung during whole breast radiotherapy. Methods:Twenty five consecutive...
full textMy Resources
Journal title
volume 8 issue 3
pages 73- 81
publication date 2011-09-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023