Nonlinear Analysis of Interaction with SVC in Stressed Power Systems: Effect of SVC Controller Parameters
Authors
Abstract:
In this paper, the effect of Static VAr Compensator (SVC) parameters on the nonlinear interaction of steam power plant turbine-generator set is studied using the Modal Series (MS) method. A second order representation of a power system equipped with SVC is developed and then by MS method the nonlinear interaction of torsional modes is assessed under various conditions and the most influencing factors are determined. The results show that the stress conditions and some SVC control parameters will adversely affect the dynamic performance of a power system by increasing the nonlinear interaction of torsional modes. In this situation, the MS method can precisely provide a reliable prediction of the torsional oscillations amplitudes and the frequency content of the output system response. As the angle and speed of turbine-generator segments are used as input signals in several controllers, the frequency content of these signals are quite important in designing such controllers. This analysis is performed on a 4-areas WSCC system, which is equipped with a SVC. The obtained results can provide some important guidelines for coordinate operation and design of FACTS controllers to reduce the risk of shaft failure arising from torsional interaction in long term.
similar resources
analysis of power in the network society
اندیشمندان و صاحب نظران علوم اجتماعی بر این باورند که مرحله تازه ای در تاریخ جوامع بشری اغاز شده است. ویژگیهای این جامعه نو را می توان پدیده هایی از جمله اقتصاد اطلاعاتی جهانی ، هندسه متغیر شبکه ای، فرهنگ مجاز واقعی ، توسعه حیرت انگیز فناوری های دیجیتال، خدمات پیوسته و نیز فشردگی زمان و مکان برشمرد. از سوی دیگر قدرت به عنوان موضوع اصلی علم سیاست جایگاه مهمی در روابط انسانی دارد، قدرت و بازتولید...
15 صفحه اولmaximum load restoration in power systems with tcsc and svc
in this paper, power system restoration in the presence of svc and tcsc in partial outage conditions is considered and a new method for maximum load restoration using different control variables is presented. control variables are tap of transformers, generation rescheduling and operating points of facts devices. objective function is restored load (to be maximized) and constraints are voltage ...
full textStability Improvement of Power System By Using SVC With PID Controller
Abstract— This paper presents the model of a static VAR compensator (SVC) which is controlled externally by a Proportional Integral Differential (PID) controller for the improvements of voltage stability and damping effect of an on line power system. The PID controller parameters has been selected by using Ziegler-Nichols tuning rule method. Both single phase and three phase faults have been co...
full textDamping of Power System Oscillations Using SVC With HPF Control
In large power systems, low frequency electro-mechanical oscillations often follow the electrical disturbances. Generally, power system stabilizers (PSS) are used in conjunction with Automatic Voltage Regulators (AVR) to damp out the oscillations. However, during some operating conditions this device may not produce adequate damping and other effective alterations are needed in addition to PSS....
full textDamping enhancement in the presence of load parameters uncertainty using reinforcement learning based SVC controller
This paper proposes a reinforcement learning based SVC controller to improve the damping of power systems in the presence of load model parameters uncertainty. The proposed method is trained over a wide range of typical load parameters in order to adapt the gains of the SVC stabilizer. The simulation results show that the tuned gains of the SVC stabilizer using Reinforcement Learning can provid...
full textDesign of a Supplementary Controller for SVC Using Immune Algorithm
This paper investigates the ability of Immune Algorithm (IA) in designing a supplementary controller for Static Var Compensators (SVC) to damp the power system inter-area oscillation. For this the parameters of the supplementary controller are determined by IA using an eigenvalue-based objective function. The numerical results are presented on a 2-area 4-machine system to illustrate the feasibi...
full textMy Resources
Journal title
volume 9 issue 2
pages 107- 116
publication date 2013-06
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com