Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

author

  • Mahmood Nazarpoor Department of Radiology, Faculty of Paramedicine, Tabriz University of Medical Sciences, Tabriz, Iran
Abstract:

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to determine the best clinical coil for future clinical application. Materials and Methods A phantom was designed to investigate the non-uniformity of coils. All evaluations were carried out using a 1.5 T clinical MRI scanner. T1-weighted inversion recovery sequence (linear phase encoding) and turbo fast low angle shot (TurboFLASH) images were used to find non-uniformity in the clinical coils. For testing the uniformity of coils, signal intensity profiles in parts of the coronal image of phantom were measured over X and Y axes. Results The results showed that body coil was the most uniform coil of all; in addition, the head and neck coil was more uniform than the head coil. The results also indicated that signal-to-noise ratio (SNR) of the head and neck coil was higher than the head and body coils. Moreover, SNR of the head coil was higher than that of the body coil. Conclusion In order to accurately find or apply an image signal intensity for measuring organ blood flow or perfusion, coil non-uniformity corrections are required.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

a contrastive analysis of concord and head parameter in english and azerbaijani

این پایان نامه به بررسی و مقایسه دو موضوع مطابقه میان فعل و فاعل (از نظر شخص و مشار) و هسته عبارت در دو زبان انگلیسی و آذربایجانی می پردازد. اول رابطه دستوری مطابقه مورد بررسی قرار می گیرد. مطابقه به این معناست که فعل مفرد به همراه فاعل مفرد و فعل جمع به همراه فاعل جمع می آید. در انگلیسی تمام افعال، بجز فعل بودن (to be) از نظر شمار با فاعلشان فقط در سوم شخص مفرد و در زمان حال مطابقت نشان میدهند...

15 صفحه اول

[Magnetic resonance imaging in the head and neck tumor diagnosis].

MRI (magnetic resonance imaging) is a new diagnostic technique that is being applied to study disease processes that involve the upper aero-digestive tract and cranial nerves of interest to otolaryngologist. Seventy four patients with head and neck tumor were enrolled to study the diagnostic efficacy of MRI in comparison with X-ray computed tomography (X-ray CT). Five cases of head and neck tum...

full text

investigation of factors affecting body temperature changes during routine clinical head magnetic resonance imaging

conclusion a higher magnetic field strength and a decrease in the hr resulted in an increase in body temperature during the mri procedure. results our investigation of the physiological response to rf heating indicated a link between increasing age and body temperature. a higher increase in body temperature was observed in older patients after a 3.0-t mri (r = 0.07, p = 0.29 for 1.5-t mri; r = ...

full text

Magnetic resonance imaging in head and neck cancer.

The scans of 120 patients with proven head and neck cancer who underwent magnetic resonance imaging (MRI) at Mt. Vernon hospital were reviewed and, where possible, compared with their clinical, computed tomography (CT) and histological findings. MRI was generally superior to both clinical examination and CT in the detection of cervical lymphadenopathy and in the assessment of primary tumour ext...

full text

Magnetic resonance imaging in head and neck radiodiagnosis: An overview

“Necessity is the mother of invention”... so goes the age old adage. The insight into the human body has always fascinated man. When diseases and disorders went beyond comprehension, man invented imaging to learn more about the internal architecture of the body. The zeal to gain more information about the underlying disease process compelled researchers, to seek out for the better imaging modal...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 11  issue 4

pages  322- 327

publication date 2014-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023