MRS Shimming: An Important Point Which Should not be Ignored
Authors
Abstract:
Introduction: Proton magnetic resonance spectroscopy (MRS) is a well-known device for analyzing the biological fluids metabolically. Obtaining accurate and reliable information via MRS needs a homogeneous magnetic field in order to provide well-defined peaks and uniform water suppression. There are lots of reasons which can disturb the magnetic field homogeneity which can be corrected by a process known as shimming. This study is intended to recall the importance of shimming and also the significant role of quality control (QC) in achieving an accurate quantification.Material and Method: An acrylic cylindrical quality control phantom was designed as an analog of brain MRS test phantoms in order to control the accuracy of the obtained signal of a 1.5 T Siemens MRI system which belonged to one of Shiraz hospitals. The signal of NAA, Cho, Cr, the combination of these metabolites and also the distilled water, which was used in this study, was evaluated using separate phantoms. A QC test was performed using Siemens QC phantom and a standard test phantom.Results: The spectrum of our home- made phantom had a significant difference with the expected spectrum. The results of checking the spectrum of metabolites separately also confirmed that there was a systemic problem that affects all the signals originated from all metabolites and even the pure distilled water. The MRS system could not pass QC tests, and peak broadening was common in all spectra. The complex spectrum of standard test phantom was not produced successfully by the MRS system.Discussion: By a simple check of the water peak characteristics, lots of information can be obtained, one of which is the status of shimming that has a considerable effect on the accuracy of the spectrum. Thus, performing an automatic or manual shimming is not a criterion of the spectrum accuracy, and performing a periodic quality control using a test phantom by a specialist is necessary.Conclusion: Briefly, the quality control of MRS and all the other clinical device must be taken seriously. Sometimes QC can be the boundary of a right or a wrong decision for the patient.
similar resources
Acute Pancreatitis – A Disease That Should Not Be Ignored!
Last week I reviewed a relatively unknown household threat to dogs and cats – bread dough intoxication. More commonly around the holidays emergency rooms see a spike in a specific type of illness in our furry companions – acute pancreatitis. This illness can manifest at any time of year, but incidence around the major winter holidays in the United States is so high that many refer to the days a...
full textWhy non-determinism in middleware should not be ignored
Unfortunately, in the practical world of IT, the theoretical solution does not apply. Indeed the cost of resolving the difficulties raised by non-determinism rapidly become prohibitive as the number of ‘components’ which need to work together rises. This is particularly applicable to distributed systems connected by middleware, with major implications for project management, application maintai...
full textTakayasu Arteritis: Criteria for Surgical Intervention Should Not Be Ignored
Takayasu aortoarteritis is a rare, chronic granulomatous panarteritis with significant morbidity amongst young patients. Current challenges include a lack of awareness about the condition, delays in diagnosis due to its varied presentation, and suboptimal methods for assessing disease activity. The development of noninvasive imaging including magnetic resonance angiography and positron emission...
full textShimming and MRS
Adjustment of the static magnetic field homogeneity, commonly known as the B0 shimming or simply shimming, is essential for magnetic resonance spectroscopy because it determines the spectral resolution which is critical for reliable metabolite quantification. Inhomogeneities in the B0 field, resulting primarily from susceptibility differences between air and tissue, are scaled with the B0 field...
full textI-14: Assisted Reproduction and Religion What Consideration Should Be and Should Not Be Relevant,
Several important issues are pertinent to an ethical discussion of the new technology today grouped under the name Assisted Reproduction Technology (ART). This is a moral imperative because each of us must decide what is to be considered ethically acceptable in assisted reproduction. Reflecting on the ethical dimension of ‘creating’ a new human life can play a major role in ensuring that in eac...
full textDifferent Stroke Scales; Which Scale or Scales Should Be Use?
Background: There has been considerable development in the clinometric of stroke. But, researcher is concerned that some scales are too generic, inherently and the insight may not be provided. The current study was conducted to determine which scale or scales should be used in stroke survivors. Methods: We selected 67 studies which published between January 2010 and December 2018 from Up to d...
full textMy Resources
Journal title
volume 8 issue 3
pages -
publication date 2018-09-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023