Monte Carlo Simulation of Prostate Intensity Modulated Radiotherapy Using PRIMO Software: A Feasibility Study

Authors

  • min Banaei Department of medical physics, faculty of medical science, Tarbiat modares University, Tehran, Iran. Email: [email protected]
  • Mohammad Javad Khosravanipour Department of medical physics, faculty of medical science, Tarbiat modares University, Tehran, Iran. Email: [email protected]
Abstract:

Introduction: Nowadays Intensity Modulated Radiotherapy (IMRT) is a common method for treating prostate cancers. Must of the Monte Carlo software cannot simulate the IMRT procedures due to inability of these soft wares to simulate the multi leaf collimator (MLC) positions or movements. A new user-friendly software based on the PENELOPE Monte Carlo code named PRIMO was published recently. This software can simulate the MLC positions in IMRT procedures. The aim of this study was to simulate the prostate IMRT fields and calculate the dose on a physical phantom. Materials and Methods: PRIMO software was used to simulate the Varian clinic 600c and Varian 80L MLC. The MLC movement was simulated in PRIMO using control points that can be obtained from the treatment planning software (TPS). A CT scans of Delta 4 phantom (ScandiDos, Sweden) were imported to the PRIMO and typical 9 fields IMRT planning was simulated on this phantom. Empirical measurements were done using Delta 4 phantom with its inside embedded diode dosimeters and computer software. Dose comparison between the simulation and empirical measurement was done using gamma evaluation method (2%, 2mm) in PRIMO software module. Results: Simulated results were in good agreement with measurement. 99% of gamma points were lower than 1. Anterior, lateral and anterior oblique fields were in complete agreement with simulation, i.e. 100% of gamma points <1. Posterior and posterior oblique fields had a few gamma points >1. Conclusion: PRIMO software can precisely simulate the prostate IMRT in relevant clinical accessible time. The difference between simulation and measurement in posterior fields may be due to the treatment couch that was not simulated in PRIMO.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Energy Modulated Photon Radiotherapy: A Monte Carlo Feasibility Study.

A novel treatment modality termed energy modulated photon radiotherapy (EMXRT) was investigated. The first step of EMXRT was to determine beam energy for each gantry angle/anatomy configuration from a pool of photon energy beams (2 to 10 MV) with a newly developed energy selector. An inverse planning system using gradient search algorithm was then employed to optimize photon beam intensity of v...

full text

Evaluation of Lung Dose in Esophageal Cancer Radiotherapy Using Monte Carlo Simulation

Background and purpose: Radiation therapy make an important contribution in the control and treatment of cancers. Lungs are the main organs at risk in esophageal cancer radiotherapy. Difference between the dose distribution due to the treatment planning system (TPS) and the patient's body dose is dependent on the calculation of the treatment planning system algorithm, which is more pronounced i...

full text

3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis

 Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...

full text

Measurement and Monte Carlo simulation for energy‐ and intensity‐modulated electron radiotherapy delivered by a computer‐controlled electron multileaf collimator

The dosimetric advantage of modulated electron radiotherapy (MERT) has been explored by many investigators and is considered to be an advanced radiation therapy technique in the utilization of electrons. A computer-controlled electron multileaf collimator (MLC) prototype, newly designed to be added onto a Varian linac to deliver MERT, was investigated both experimentally and by Monte Carlo simu...

full text

Monte Carlo simulation of RapidArc radiotherapy delivery.

RapidArc radiotherapy technology from Varian Medical Systems is one of the most complex delivery systems currently available, and achieves an entire intensity-modulated radiation therapy (IMRT) treatment in a single gantry rotation about the patient. Three dynamic parameters can be continuously varied to create IMRT dose distributions-the speed of rotation, beam shaping aperture and delivery do...

full text

Developing a software for simulation of gaseous detectors with Monte carlo method in c++ programming language

In this paper we consider a gaseous detector and supposed, because of pass of an ionizing radiation, an electron created inside it. By numerical simulation with monte carlo method and concluding the impacts, scatterings and creation of secondary electrons, we find the trajectory of initial and secondary electrons. Dependence of number of secondary electrons to applied electrical field is invest...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  176- 176

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023