Monte Carlo Dose Calculation of 90 Sr/ 90 Y Source in Water Phantom
author
Abstract:
Introduction: 90 Sr/ 90 Y source has been used for the intravascular brachytherapy to prevent coronary restenosis in the patients who have undergone angioplasty. The aim of this research is to determine the dose distribution of 90 Sr/ 90 Y source in a water phantom. Materials and Methods: In the present work, MCNP code has been applied to calculate the dose distribution around a 3 cm length of 90 Sr/ 90 Y source in a 30×30×30 cm 3 water phantom. Also, the exact geometry of the source has been used in this simulation. Tally *F8:e which is suitable for beta ray dosimetry has been evaluated with less than %5 relative error in a sphere having 0.2 mm radius. Results: The isodose curve for 10, 20, 40, and 90% depth dose (PDD) were derived based on the calculated dose curves along the parallel and perpendicular axis to the source. Discussion and Conclusion: The results obtained in this work are in a good agreement with the experimental result published by Buckley et al. and the International Atomic Energy Agency (IAEA) report in a water phantom. Therefore, the result of this research can be used in the intravascular brachytherapy.
similar resources
monte carlo dose calculation of 90 sr/ 90 y source in water phantom
introduction: 90 sr/ 90 y source has been used for the intravascular brachytherapy to prevent coronary restenosis in the patients who have undergone angioplasty. the aim of this research is to determine the dose distribution of 90 sr/ 90 y source in a water phantom. materials and methods: in the present work, mcnp code has been applied to calculate the dose distri...
full textMonte Carlo and experimental relative dose determination for an Iridium-192 source in water phantom
Background: Monte Carlo and experimental relative dose determination in a water phantom, due to a high dose rate (HDR) 192Ir source is presented for real energy spectrum and monochromatic at 356 keV. Materials and Methods: The dose distribution has been calculated around the 192Ir located in the center of 30 cm ×30 cm ×30 cm water phantom using MCNP4C code by Monte Carlo method. Relati...
full textMonte Carlo calculation of proton ranges in water phantom for therapeutic energies
Introduction: One crucial point when calculating the distribution of doses with ions is the uncertainty of the Bragg peak. The proton ranges in determined geometries like homogeneous phantoms and detector geometries can be calculated with a number of various parameterization models. Several different parameterizations of the range-energy relationship exist, with different level...
full textmonte carlo and experimental relative dose determination for an iridium-192 source in water phantom
background: monte carlo and experimental relative dose determination in a water phantom, due to a high dose rate (hdr) 192ir source is presented for real energy spectrum and monochromatic at 356 kev. materials and methods: the dose distribution has been calculated around the 192ir located in the center of 30 cm ×30 cm ×30 cm water phantom using mcnp4c code by monte carlo method. relative dose v...
full textDose distribution and dosimetry parameters calculation of MED3633 palladium-103 source in water phantom using MCNP
Background: Palladium-103 (103Pd) is a brachytherapy source for cancer treatment. The Monte Carlo codes are usually applied for dose distribution and effect of shieldings. Monte Carlo calculation of dose distribution in water phantom due to a MED3633 103Pd source is presented in this work. Materials and Methods: The dose distribution around the 103Pd Model MED3633 located in the center of 30×...
full textMonte Carlo and experimental relative dose determination for an Iridium-192 source in water phantom
Theoretical and experimental studies have been applied for dosimetric parameters determination of the brachytherapy sources (1-3). Usually, Monte Carlo method has been used to define such quantities as the anisotropy dose function, the radial dose function, and the dose calculation close to the source in brachytherapy (4-6). Ir source is used widely in brachytherapy to treat localized tumors ne...
full textMy Resources
Journal title
volume 5 issue Issue 1,2
pages 67- 72
publication date 2008-06-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023