Monte Carlo Determination of Full Energy Peak Efficiency for HPGe Detector and Self-Absorption Correction of Environmental Samples
Authors
Abstract:
The Monte Carlo method was used to determine full energy efficiency of a high-purity germanium (HPGe) coaxial detector within an energy range of 53.2-2614 keV. Also, measurement was carried out for a standard Marinelli beaker of 600cm3, which was placed into the reference material of mixed gamma. The plot of the experimentally derived efficiency versus the incident gamma radiation energy showed variations at certain energies which is attributed to the detector’s characteristics. The results obtained by the Monte Carlo method and those of the experimental measurements resulted in a standard deviation of 2.3 to 7%. The method was also applied to determine self-absorption correction of the environmental radioactive materials which gave rise to a deviation of 3–12%.
similar resources
Development of a self-absorption correction method used for a HPGe detector by means of a Monte Carlo simulation
Quantitative analysis for food products and natural samples, to determine the activity of each radionuclide, can be made by using a high-purity germanium (HPGe) gamma-ray spectrometer system. The analysis procedure is, in general, based upon the guidelines established by the Nuclear Safety Division of the Ministry of Education, Culture, Sports, Science and Technology in Japan (JP MEXT). In the ...
full textapplication and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples
ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...
15 صفحه اولEfficiency determination of HPGe detector by simulation and experimental methods for solid volume source
Analyzes of environmental samples regarding their radioactivity is of important concern for health purposes. We need standard sources to determine radioactive components and their activities. These sources are usually produced regarding type of the sample. One of the fundamental and precise tools to recognize radioactive materials and their activities is HPGe detector. To reach this goal, the d...
full textDetermination of Full Energy Peak Efficiency of NaI(Tl) Detector Depending on Efficiency Transfer Principle for Conversion Form Experimental Values
In this work we calibrated the NaI(Tl) scintillation detectors (5.08 × 5.08 cm and 7.62 × 7.62 cm) and the Full Energy Peak Efficiency (FEPE) for these detectors have been calculated for point sources placed at different positions on the detector axis using the analytical approach of the effective solid angle ratio. This approach is based on the direct mathematical method reported by Selim and ...
full textDerivation of an efficiency-calibration simulation for a well-type HPGe detector using the Monte Carlo approach and analytical techniques
Simulation is a simple method that allows for facile estimation of a detector response function when the specifications of the investigated sample and the sample-detector geometry are known. In this study, the dependence of the full-energy peak efficiency on the sample and detector specifications was studied via analytical techniques and the Monte Carlo approach in the energy range of 150e2000 ...
full textMy Resources
Journal title
volume 28 issue جلد 41
pages 50- 53
publication date 2007-11-22
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com