Modification of Source Strength in Low-Dose-Rate Lung Brachytherapy with 125I and 103Pd seeds

Authors

  • A R Mehdizadeh 2 Department of Biomedical Physics and Engineering, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran 3 Advanced Health Technologies Research Center, Shiraz University of Medical Sciences, Shiraz, Iran Mobile No. : +989176880190
  • H Mostaghimi 2 Department of Biomedical Physics and Engineering, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran 3 Advanced Health Technologies Research Center, Shiraz University of Medical Sciences, Shiraz, Iran Mobile No. : +989171009171
  • H Rezaei 1 Department of Radiology, School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran
Abstract:

Background: A new treatment approach for most patients who have undergone early stage non-small-cell lung carcinoma (NSCLC), is wedge resection plus permanent implant brachytherapy. However, the specification of dose to medium at low energies especially in heterogeneous lung is unclear yet.Objective: The present study aims to modify source strength for different configurations of 125I and 103Pd seeds used in lung permanent implant brachytherapy.Methods: Different arrays of 125I and 103Pd seeds were simulated by MCNPX code in protocol-based water vs. actual 3D lung environments. Absorbed dose was, then, scored in both mediums. Dose differences between both environments were calculated and source strength was modified for the prescription point. In addition, lung-to-water absorbed dose ratio was obtained and presented by precise equations.Results: Due to significant differences in prescription dose, source strength was modified 16%-19% and 37%-43% for different configurations of 125I and 103Pd seeds, respectively. In addition, depth-dependent dose differences were observed between the actual lung and protocol-based water mediums (dose difference as a function of depth).Conclusion: Modification of source strength is essential for different arrangements of 125I and 103Pd seeds in lung implantation. Modified source strength and presented equations are recommended to be considered in future studies based on lung brachytherapy.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Modification of Source Strength in Low-Dose-Rate Lung Brachytherapy with 125I and 103Pd Seeds

BACKGROUND A new treatment approach for most patients who have undergone early stage non-small-cell lung carcinoma (NSCLC) is wedge resection plus permanent implant brachytherapy. However, the specification of dose to medium at low energies especially in heterogeneous lung is unclear yet. OBJECTIVE The present study aims to modify source strength for different configurations of 125I and 103Pd...

full text

New National Air-Kerma-Strength Standards for 125I and 103Pd Brachytherapy Seeds

The new U.S. measurement standard for the air-kerma strength from low-energy photon-emitting brachytherapy seed sources is formally described in detail. This instrument-based standard was implemented on 1 January 1999, with its salient features and the implications of differences with the previous standard given only through a series of informal communications. The Wide-Angle Free-Air Chamber (...

full text

The Effect of Scattering from Leg Region on Organ Doses in Prostate Brachytherapy for 103Pd, 125I and 131Cs Seeds

Introduction Dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. Three radioisotopes, namely, 125I, 103Pd, and 131Cs, are extensively used in this method. In this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for the ...

full text

Salvage low-dose-rate 125I partial prostate brachytherapy after dose-escalated external beam radiotherapy

PURPOSE To report outcomes on 5 patients treated with salvage partial low-dose-rate (LDR) 125-iodine ((125)I) permanent prostate seed brachytherapy (BT) for biopsy-proven locally persistent prostate cancer, following failure of dose-escalated external beam radiotherapy (EBRT). MATERIAL AND METHODS A retrospective review of the Fox Chase Cancer Center prostate cancer database identified five p...

full text

Dosimetry Comparison of Water Phantom and Complete Eye Definition for 125I and 103Pd Brachytherapy Plaques

Introduction: In this paper, by complete definition of human eye containing the various parts and their materials, the difference between this model and a homogeneous water phantom are compared for two ophthalmic plaques using 125I and 103Pd. Material and methods: The simulation of the two phantoms were performed in the MCNP-4C code and by using the geometry of a three-dimensional eye, differen...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 7  issue 3

pages  -

publication date 2017-09-01

By following a journal you will be notified via email when a new issue of this journal is published.