Abstract:
The present study deals with a new method for measuring the power of a reactor. This method uses gamma and neutron radiation resulted from the entire reactor structure, without changing its structure (online). In terms of functionality, this method can measure the reactor power in real-time and report it instantly. In order to obtain the relationship between reactor power and gamma and neutron leakage radiation by simulation, the values of the F5 tally are calculated at different distances from the reactor wall, using the MCNP5 code (Monte Carlo N-Particles). Then, we plot the diagram to observe the variation trend. However, an increase in the distance from the reactor reduces both the amount of radiation and the energy of the radiation particles until the neutron leakage radiation reaches zero within five meters of the body, due to its good insulation. However, this number is only about four meters for gamma irradiation. The reactor power can be calculated by measuring the flux at the given point and any time by determining the point for a range of leakage radiation reduction to background and the linear relationship between power and leakage flux.
similar resources
Estimation of neutron and gamma dose in the MNSR research reactor
In this study, the neutron and gamma doses in the dry channel and in the internal irradiation site of the Miniature Neutron Source research reactor (MNSR) has been calculated and measured. The MNSR reactor is a light water reactor with a maximum power of 30 kW and equipped with various irradiation facilities, including five irradiated sites, five irradiation sites and a dry channel. The interna...
full textPrimary Loop Study of a VVER-1000 Reactor With special Focus on Coolant Mixing
In this paper a detailed model of a VVER1000 reactor pressure vessel (RPV) with the extension of simplified primary loops is presented (Loop model). The primary loop components like steam generators and pumps are modelled by the outer shapes and additional source terms for energy and momentum exchange. The RPV model part is tested without primary loops and compared with former results obtained ...
full textInvestigating the Effect of Gamma Ray Source Activity on Down-hole Nuclear Density Tool’s Reading Using Simulation by MCNP Code
Developing well logging methods will increase the applications of logs related to all the other geology sciences. Well logging curves introduce the essential information to evaluate reservoir characterizations, rock type and also formation fluid properties quantitatively. One of the most important parts of drilling and completion operations which affect making decision about the future planes i...
full textReactor Power Distribution Calculation in Research Reactors Using MCNP
In reactor calculations, a detailed 3-D power density distribution is required for core optimization studies and safety analyses. The general Monte Carlo based neutral particle transport tool, MCNP [1], has the capability to obtain detailed power density distribution in a reactor through its criticality calculation mode (KCODE mode). However, there is no standard tally type in MCNP that is able...
full textمحاسبات نوترونیک قلب راکتور vver-1000 بوشهر توسط کد mcnp
یکی از موارد مهم در طراحی راکتور های هسته ای، لحاظ کردن فاکتور های ایمنی در آنها می باشد. از جمله مهمترین این فاکتورها، کنترل توان راکتور و خاموش سازی آن در هنگام وقوع حادثه است که میله های کنترل نقش بسیار موثری در این زمینه دارند. باتوجه به پیشرفت روز به روز کدها ی هسته ای، استفاده از کد mcnp به عنوان یک کد پیشرفته باعث هر چه واقعی تر شدن نتایج حاصل از شیبه سازی می شود. در این تحقیق اطلاعات لا...
15 صفحه اولExperience in Simulation of Startup Measurements in the Vver-440 Reactor Using the Kiko3d Code
The purpose of this work carried out by MTA KFKI Atomic Energy Research Institute in Hungary, is to develop and validate a method for predicting the ex-core detector responses in the Russian pressurized water type VVER reactors. The time and space dependent neutron flux in the core during these measurements have been calculated by the KIKO3D nodal diffusion code. For calculating the ionization ...
full textMy Resources
Journal title
volume 8 issue 5
pages 67- 73
publication date 2020-09
By following a journal you will be notified via email when a new issue of this journal is published.
No Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023