Mitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach
Authors
Abstract:
This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral control (PIC), and Random Pulse Width Modulated proportional-integral control (RPIC). The simulation results with and without the shunt active power filter in the system are presented and analyzed. The simulation results show that the RVSC controller has a better performance than other control strategies, allowing compensation of reactive power, reducing high frequency harmonics thus overcoming the problem of electromagnetic interference (EMI), reducing dc current injection below the limit specified in IEEE-1547 standard, and also reducing the harmonic level below the limit specified in IEEE-519 standard.
similar resources
mitigation of switching harmonics in shunt active power filter based on variable structure control approach
this paper presents a novel control approach used in shunt active power filter based on variable structure control combined with random pwm technique (rvsc) that provides robust, fast, and more favorable performance for active power filter. this control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...
full textComparative Analysis on Control Methods of Shunt Active Power Filter for Harmonics Mitigation
This paper presents an overview of different control methods which are applied on Shunt Active Power Filter to achieve harmonics reduction and power factor improvement. In recent decades, the world has seen an expansion in the use of non-linear loads. These loads draw a non-sinusoidal current from the source and distribute them throughout the system. As a result the power quality degrades. Ther...
full textControl Algorithms of Shunt Active Power Filter for Harmonics Mitigation: A Review
Current harmonics is one of the most significant power quality issues which has attracted tremendous research interest. Shunt active power filter (SAPF) is the best solution to minimize harmonic contamination, but its effectiveness is strictly dependent on how quickly and accurately its control algorithms can perform. This manuscript reviews various types of existing control algorithms which ha...
full textHarmonics Mitigation Using Active Power Filter
This paper is proposed to reconsider the development of active power filter (APF) technologies that are routinely utilized to mitigate harmonics in utility power lines. This reconsider can furthermore be considered as a “tutorial-type paper” as it provides a holistic coverage of the APF technologies by omitting the tedious details, but without losing the major essence of the subject matter. It ...
full textAdaptive Hysteresis Based Fuzzy Controlled Shunt Active Power Filter for Mitigation of Harmonics
Active filters are widely employed in distribution system to reduce the harmonics produced by non-linear loads result in voltage distortion and leads to various power quality problems. In this work the simulation study of a Adaptive hysteresis based fuzzy logic controlled shunt active power filter capable of reducing the total harmonic distortion i s presented. The advantage of fuzzy control is...
full textMy Resources
Journal title
volume 1 issue 2
pages 83- 88
publication date 2013-12-30
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023